Warranty: | 2 Years |
---|---|
Display: | No Display |
Installation: | Direct Connected |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Type
|
Function
|
AMC16MA
|
Three Phase: 2 Channels Inlet I, U, P, Q, EP, EQ, S
Single Phase: 36 Channels Outlet (Three Phase 12 Channels Outlet) I, U, P, Q, EP, EQ
1DO, RS485 (Modbus-RTU)
|
AMC16MAH
|
Measure the Total Three Phase Incoming Line Voltage, Two Three-phase Incoming Lines I, kW, kvar, cosΦ, kWh, kvarh (Required Configure AKH-0.66W 100A/20mA Current Transformer); Measure Incoming Line Voltage, Incoming Line Current, Outgoing Line Current 2-15 Sub-Harmonics and Total Harmonics; 1 RS485 Communication; 1DO, AC220V Power Supply
|
AMC16Z-ZA
|
A+B Independent 2 Channels Three-phase Inlet U, I, P, Q, S, PF, EP, EQ, UN to PG, Neutral Current 2-63rd Harmonic of Voltage and Current 6 Channels Passive Switching Input 2 Channels Switching Output RS485 (Modbus-RTU) Communication
|
AMC16Z-ZD
|
Measurement of A+B Independent 2-way DC Bus Voltage, Current, kW, kWh, 6DI+2DO+1RS485 (Modbus-RTU)
|
AMC16Z-KA
|
A+B Independent 2 Way Unilateral 24 Active Switch States
|
AMC16Z-KD
|
A+B Independent 2 Way Unilateral 24 Passive Switch States
|
AMC16Z-FAK24
|
Measure A+B Two-way AC Outlet, Total 24 Branch Full Electric Parameter and Switch Value Status, 1 RS485 (Modbus-RTU)
|
AMC16Z-FAK48
|
Measure A+B Two-way AC Outlet, Total 48 Branch Full Electric Parameter and Switch Value Status, 1 RS485 (Modbus-RTU)
|
AMC16Z-FDK24
|
Measure A+B Two-way DC Outlet, Total 24 Branch Full Electric Parameter and Switch Value Status, 1 RS485 (Modbus-RTU)
|
AMC16Z-FDK48
|
Measure A+B Two-way DC Outlet, Total 48 Branch Full Electric Parameter and Switch Value Status, 1 RS485 (Modbus-RTU)
|
Technical Parameter
|
Value
|
|
Distribution System
|
AC
|
|
Measurement of Electric Parameters
|
Three-phase 2 Channels Inlet I, U, P, Q, EP, EQ, S
|
|
Single-phase 36 Channels Outlet (Three-phase 12 Channels Outlet) I, U, P, Q, EP, EQ
|
||
Voltage
|
Rate Voltage
|
220V AC
|
Range
|
40-400V AC
|
|
Overload
|
1.2 Times (Continuous), 10 Times (1 Seconds)
|
|
Current
|
Inlet CT
|
XXA/5A
|
Inlet Range
|
0-10A
|
|
Outlet CT
|
100A/20mA
|
|
Outlet Range
|
0-120%
|
|
Overload
|
1.2 Times (Continuous), 10 Times (5 Seconds)
|
|
Frquency
|
45-65Hz
|
|
Accuracy
|
Inlet
|
Class 1.0
|
Outlet
|
Class 2.0
|
|
Auxiliary Power Supply
|
AC 85-265V / DC 100-350V
|
|
Insulation Resistance
|
100MΩ
|
|
Environment
|
Temperature
|
Operation: -10-45ºC Storage: -25-70ºC
|
Humidity
|
Relative Humidity ≤95%
|
|
Altitude
|
≤2000m
|
|
Switching Output
|
5A 250V AC / 5A 30V DC
|
|
Communication
|
RS485 (Modbus-RTU)
|
|
Installation
|
Din 35mm
|
Suppliers with verified business licenses