Product Description
DTSD1352-4S series DIN-rail type multi-circuit power meter is mainly used for the full electric parametermeasurement of multiple circuits, and can be connected to the current input of 4 three-phase circuits or 12single-phase circuits at the same time. It can measure parameters such as voltage and current, power, power factor,phase angle, unbalance, and harmonics
Product Parameters
DTSD1352-xSyD
x-channel three-phase current circuit
y-channel single-phase current circuit
Voltagespecification |
Instrument model |
Current specification |
Matching current transformer |
note |
3x220/380V |
DTSD1352-xSyD |
3×250A |
AKH-0.66/W-20Y Class 0.2 |
For three-phase |
3×100A |
AKH-0.66/Z-15Y Class 0.2 |
1×100A |
AKH-0.66/W-12Y Class 0.2 |
Parameter
Auxiliary Power Supply |
AC/DC 85~265V; Power Consumption≤10VA |
Input Single |
Frequency |
45~65Hz |
Voltage |
Rated value: AC 3×220V/380V |
Overload:1.2 times rated value(continuous) |
2 times rated value/1 second |
Power consumption:≤ 0.5VA(per channel) |
Input signal |
Current |
Rated value:AC 250A,100A;(external closed port transformer) |
Overload:1.2 times rated value(continuous) |
10times rated value/1 second |
Power consumption ≤ 0.5VA(per channel) |
Measurement accuracy |
Frequency 0.05Hz,voltage and current class 0.5,
active energy class 1,.reactive energy class 2 |
2-31st harmonic accuracy:±1% |
Function |
Pulse output |
Output mode: optocoupler pulse with the open collector(one out of two with active input) |
Function |
Communication |
RS485 interface, Modbus-RTU protocol/QZTT 1017-2015 |
technical specification for China Tower smart meter |
Baud rate 1200~38400 |
Switch-value |
Input |
4-channels passive dry contact input, built-in power supply |
2-channels active wet node input, identify engine oil and power connection(or pulse output) |
output |
Output mode: relay normally open contact output |
Contact rating: AC 250V/3A DC 30V/3A |
Security |
Power frequency withstands voltage |
>AC 2kV/1min |
Insulation resistance |
Input and output end to housing |
Environment |
Working temperature:-20ºC~+60 C |
Storage temperature:-40ºC~+70ºC |
Relative humidity≤95% no condensation |
Altitude≤2500m |
Electromagnetic compatibility |
Better than level 3 |
Function
Function |
Description |
Measurement of energy |
All electrical parameters of x-channel three-phase andy-channel single-phase circuits are measured |
Electrical parameters |
U,1,F,P,Q,S,PF |
Harmonic |
2-31st voltage and current harmonic |
Extreme value record |
U, I, P |
Alarm output |
Overvoltage, Over current, Phase break, DI linkage |
Rate setting |
4 rate time zone 14 |
Pulse output |
Output mode: optocoupler pulse with open-collector(one out of two with active input) |
communication |
RS485 interface, Modbus-RTU, Baud rate 1200~38400 |
DI |
4-channels passive dry contact input, built-in power supply2-channels active wet node input, identify engine oil and power connection(or pulse output) |
DO |
Output mode: relay normally open contact output Contact rating: AC 250V/3A DC 30V/3A; |
Wiring Diagram
Front Panel
Application
Company Profile