• Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
  • Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
  • Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
  • Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
  • Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
  • Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive

Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive

Kind: New-Type Transmitter
Type: DC Transmitter
Phase: Single
Wire-Assembly Type: Two-wire Transmitter
Accuracy Grade: 0.2G
Certification: CCC
Samples:
US$ 31.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Standard
  • Product Parameters
  • Dimension
  • Wiring
  • Application Case
  • Company Profile
Overview

Basic Info.

Model NO.
BM100-DV
Customized
Customized
Transport Package
Carton
Specification
17.00cm * 15.00cm * 13.00cm
Trademark
ACREL
Origin
China
HS Code
9030339000
Production Capacity
200000

Product Description

BM100 series signal isolators can measure the electrical parameters such as current and voltage or non-electrical parameters such as temperature and resistance at high speed and accurately, and can be converted into standard analog signal output after the isolation device. It can be directly connected with pointer meter and digital display meter, and can also be connected with automatic control instrument (such as PLC), various A/D converters and computer systems. It is widely used in electric power,railway,petrochemical,metallurgy,chemical industry,food,warehousing and other industries.
BM100-DV  is a voltage input, proportional output 1500V isolated DC 0/4-20mA, 0/1-5V, 0/2-10V signal. There is a surge protection circuit in the module, which is also suitable for harsh environment work.
Product Description

Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive

Standard

GB/T13850-1998
"Electric measuring transmitter for converting AC electric quantity into an analog quantity or 
digital quantity"

Product Parameters
 
Channel type
Single-way input and single-way output,
single-way input and double-way output,
double-way input and double-way output
Input type
Current/Voltage/Thermal resistance Pt100/Resistance/Thermocouple
Input signal
DC 0~5V /1~5V /0~ 10V
Output signal
0~20mA /4~20mA (Safe side input); Load resistance: ≤550Ω
0~5V /1~5V (Safe side input); Load resistance: ≥330K
0~10V (Safe side input); Load resistance: ≥500K
Transmission accuracy
0.2%
Temperature modulus
50ppm/ºC (Voltage output: 100ppm/ºC)
Response time
5ms to reach 90% of the final value
(RTD Pt100/resistance/thermocouple input: 1s to reach 90% of final value)
Power supply
20~35V DC or 85~265V AC/DC
Work temperature
-20ºC~+60ºC
Fix mode
Rail installation
Dielectric strength
≥2000V AC/1 min (Among input//output//power supply)
Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
Dimension

Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive

Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
 
Wiring
Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/PassiveSingle or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/PassiveSingle or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/PassiveSingle or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive

 

Application Case
Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive
project brief:

The ground source heat pump equipment is inconvenient to operate, and the equipment must be started and stopped on site according to the process. Energy waste is more serious, the motor of the equipment has been in a constant power output, can not adjust the power output according to the external environment and other factors.
Through the Arcel7000 enterprise energy management and control platform, communicate with PLC to collect field related parameters such as temperature, pressure, etc. After the calculation of the mathematical model, the command is sent to the PLC to control the output frequency of the inverter and achieve the result of controlling the output power of the motor.
Company Profile

Single or Dual Input Voltage Loop Isolator 0-5V/0-10VDC/4-20mA Output Active/Passive

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now