• Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
  • Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
  • Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
  • Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
  • Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
  • Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus

Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus

Kind: Two-wire Transmitter
Type: AC Transmitter
Phase: Single
Wire-Assembly Type: Two-wire Transmitter
Accuracy Grade: 0.5G
Certification: CE
Samples:
US$ 21.7/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
BA20(II)-AI/I
Customized
Non-Customized
Input Current
AC0-(0.5-200)A
Output Signal
4-20mA/0-20mA
Power Supply
DC12/24V
Option 1
Split Core Type
Option 2
Mobus RS485
Optional 3
True RMS Measurement
Warranty
2 Years
Transport Package
Paper Carton
Specification
42.5*82*58mm
Trademark
Acrel
Origin
Jiangsu China
HS Code
8504311000
Production Capacity
99999pieces/Year

Product Description

Product Description                 
1.OverviewThe intelligent BA series current sensor uses the principle of electromagnetic induction to measure the AC current in the power grid in real time and uses constant current and linear compensation technology to isolate and transform it into a standard DC signal output,or through the RS485 interface (Modbus-RTU protocol) to transmit the measurement data. DC24V or 12V safety voltage power supply, can be widely used in the field of industrial automation. BA50L(II)-AI is an AC residual current transformer, which mainly detects the leakage current of the electrical system, can grasp the status of electrical circuits and equipment at anytime,and prevent fires and other accidents caused by leakage.The shape has one-piece and split-type,as shown in Figure 1 and Figure 2.
Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus

2.Product Model
Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
3.Product Specification
Technical Parameter Index
Accuracy Class Class 0.5
Input Nominal value
Current AC60A, 300A, 600A, etc. 
AC0~(60~600)A
Overload
Continuous 1.2 times,
 instantaneous current 10 times /1S
Absorbed power ≤1VA
Frequency response
25Hz~ 800Hz, 
especially suitable for industrial frequency occasions
output Nominal value DC4~20mA,or0~20mA,0~5V,0~10V ,etc.
Load Resistance
When DC12V power supply, current output is≤250Ω 
When DC24Vpower supply, current output is≤500Ω, 
When voltage output is≥1KΩ
Communication RS485 interface/Modbus-RTU
Response time ≤400ms
Power supply Voltage DC 12V or 24V
Power consumption ≤1W
Insulation resistance >100MΩ
Compressive strength Between input /output and power supply 2.0KV/1min,50Hz
Temperature Coefficient -10ºC~+55ºC,≤400ppm/ºC
Environment Temperature Work:-10ºC~+55ºCStorage:-25ºC~+70ºC
Environment Humidity ≤93%RH,no condensation,no corrosive gas place
Environment Altitude ≤2000m
Installation method TS35 rail,or uses crews to fix the cabinet
Note: 1.0~10V output is only suitable for DC24V power supply;
2.The communication function is optional.
 
Optional functions:
1. Modbus RTU RS485
2.Split core types
3.Ture real value,RMS
Note: 0~10V output is only suitable for DC24V power supply;
The communication function is optional.
 
Optional functions:
1. Modbus RTU RS485
2.Split core types
3.Ture real value,RMS
Type Function Option
BA20(II)-AI/I In:AC0-(0.5-200)A;Out:4-20mA/0-20mA;Power supply:DC24V/12V /F:Split type
/C:RS485
(Modbus-RTU)
/T:True RMS measurement
BA20(II)-AI/V In:AC0-(0.5-200)A;Out:1-5V/0-5V;Power supply:DC24V/12V
BA50(II)-AI/I In:AC0-(60-600)A;Out:4-20mA/0-20mA;Power supply:DC24V/12V
BA50(II)-AI/V In:AC0-(60-600)A;Out:1-5V/0-5V;Power supply:DC24V/12V
BA50L(II)-AI/I In:AC0-(0.1-1)A;Out:4-20mA/0-20mA;Power supply:DC24V/12V /F:Split type
BA50L(II)-AI/V In:AC0-(0.1-1)A;Out:1-5V/0-5V;Power supply:DC24V/12V /C:RS485
(Modbus-RTU)

Packing & Delivery                                           
1. Payment:100% TT in advance
2. Delivery:in 15 working days after payment received.
3. Delivery ways:By sea,air or international courier like Fedex,TNT,DHL and UPS.
Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
Company Profile                           

Acrel Co., Ltd. [Stock Code: 300286.SZ] is one of the few leading companies in China who provides various systematic solutions of power monitoring, power control, energy management and electrical safety for smart grid users. Since June 2003, we has always been focused on the research, production and sales of intelligent electric meters. We concentrates on providing products and services to help customers improve electricity efficiency and safety. So far we had the following comprehensive solutions for different applications: 35(10)/0.4kV substation automation system, building mounted photovoltaic (BMPV) system, power quality management system, energy management system, electrical fire monitoring system, IT distribution system for medical locations, precise distribution management system, power supply monitoring system for fire protection equipment, fire emergency lighting and evacuate indicating system, fire resistant doorsets monitoring system, smart lighting control system, Lithium battery management system and electric vehicle charging system.
Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus
Certifications
Measuring CT 0-200A Input AC Smart Current Sensors Ba20 (II) -Ai/I Split Core Current Transducer 4-20mA Output with RS485 Modbus

FAQ
1. who are we?
We are based in Shanghai, China, start from 2003,sell to Domestic Market(63.00%),Southeast Asia(12.00%),Southern Europe(5.00%),South Asia(5.00%),Northern Europe(3.00%),North America(2.00%),South America(2.00%),Oceania(2.00%),Mid East(2.00%),Eastern Europe(00.00%),Africa(00.00%),Eastern Asia(00.00%),Western Europe(00.00%). There are total about 501-1000 people in our office.

2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.what can you buy from us?
Energy Meter,Hall Effect Current Sensor,Current Transformer,Current Transducer,Signal Isolator,Wireless Temperature Monitoring

4. why should you buy from us not from other suppliers?
Acrel Co., Ltd. [Stock Code: 300286.SZ] is one of the few leading companies in China who provides various systematic solutions of power monitoring, power control, energy management and electrical safety for smart grid users.

5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,DDP,DDU,Express Delivery;
Accepted Payment Currency:USD,EUR,CNY;
Accepted Payment Type: T/T,MoneyGram,PayPal,Western Union,Cash;
Language Spoken:English,Chinese,French
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now