Acrel 3p4w AC Current Input Electrical Transducer for Automation

Product Details
Customization: Available
Kind: 3 Phase Transducer
Type: AC Transmitter
Still deciding? Get samples of US$ 95.2/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (24)
  • Acrel 3p4w AC Current Input Electrical Transducer for Automation
  • Acrel 3p4w AC Current Input Electrical Transducer for Automation
  • Acrel 3p4w AC Current Input Electrical Transducer for Automation
  • Acrel 3p4w AC Current Input Electrical Transducer for Automation
  • Acrel 3p4w AC Current Input Electrical Transducer for Automation
  • Acrel 3p4w AC Current Input Electrical Transducer for Automation
Find Similar Products
  • Overview
  • Specification
  • Overview
  • Dimension
  • About US
Overview

Basic Info.

Model NO.
BD-4P
Phase
Three
Wire-Assembly Type
Three-wire Transmitter
Accuracy Grade
0.5G
Certification
IEC-688
Customized
Non-Customized
Circuits
3 Channels
Input
3 Phase AC 0-1/5A
Output
4-20mA
Power
AC/DC 85-270V
Transport Package
Carton
Trademark
Acrel
Origin
China
Production Capacity
50000

Packaging & Delivery

Package Size
20.00cm * 25.00cm * 20.00cm
Package Gross Weight
2.000kg

Product Description

Specification

Specification

Measurement 3-phase AC Current
Accuracy Class 0.5
Input 0-1A/0-5A AC and 0~100V/0~220V/0~380V AC
Output 4-20mA/0-20mA DC or 0~5V/0-10V DC or RS485 (ModBus-RTU)
Power Supply 85-265V AC (50Hz) or 100~350V DC or 24V/48V DC
Wiring 3-phase 3-wire
Application Paired with PLC for industrial Automation, Used for Metering
Response Time ≤ 400ms
Installation 35mm DIN Rail/Screw fixed
Standard & Certificate CE
 
Overview

Overview
 

    Series BD electric transmitters is a device which can isolate and transmit electric parameters, suchascurrent,voltage, frequency, power, power factor, into linear DC analog signal or digital signal. It meet the requirementsofNational standard GB/T13850-1998, IEC-688.

Acrel 3p4w AC Current Input Electrical Transducer for Automation
Model Name Measuremnt Input Output Wiring
BD-3P

3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire
BD-4P

3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire
BD-3Q

3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire
BD-4Q

3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire
BD-3/P/Q/I

3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire
BD-4/P/Q/I

3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire
BD-PF

3-phase

Power-Factor

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire
BD-F

3-phase

Frequency

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire
BD-3E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire
BD-4E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire
 
Dimension

Dimension
Acrel 3p4w AC Current Input Electrical Transducer for Automation

Model Name Outline Size (mm)
L H D W N
BD-3P 110 75.4 128 35 111.7
BD-4P 110 75.4 128 35 111.7
BD-3Q 110 75.4 128 35 111.7
BD-4Q 110 75.4 128 35 111.7
BD-3/P/Q/I 110 75.4 128 35 111.7
BD-4/P/Q/I 110 75.4 128 35 111.7
BD-PF 110 75.4 128 35 111.7
BD-F 110 75.4 128 35 111.7
BD-3E 110 75.4 128 35 111.7
BD-4E 110 75.4 128 35 111.7


 

About US

About Us

Acrel 3p4w AC Current Input Electrical Transducer for AutomationAcrel 3p4w AC Current Input Electrical Transducer for AutomationAcrel 3p4w AC Current Input Electrical Transducer for AutomationAcrel 3p4w AC Current Input Electrical Transducer for AutomationAcrel 3p4w AC Current Input Electrical Transducer for AutomationAcrel 3p4w AC Current Input Electrical Transducer for Automation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier