• Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
  • Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
  • Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
  • Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
  • Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
  • Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Voltage: DC24V
Power Consumption: ≤2va
Monitored System Voltage: AC 242V
Rated Frequency: 45-60Hz
Locating Voltage: Under 25V
Locating Current: Under 1mA
Samples:
US$ 680/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
AIL150-8
Locating Circuits
8 Circuits,Max up to 24 Circuits
Communication
Can
Transport Package
Paper Carton
Specification
0.5kgs
Trademark
ACREL
Origin
Jiangsu, China
HS Code
9031809090
Production Capacity
1000PCS/Week

Product Description

Product Description
 

Medical insulation fault locator for hospital equal to Bender EDS440

It can detect ASG150 test signal generator' s signal which is injected into the system,It can accurately locate the insulation fault circuit. AIL 150-8

insulation fault locator can locate 8 channel insulation fault locations,3 pcs AIL150-8 can be used in 1 hospital isolated power system to locate up to

24 circuit fault locations.


Functions and Parameters

parameters of 24 circuit hospital medical insulation fault

locator :


*Insulation fault location in medical IT system
 
*8 circuit fault location used with test signal generator
 
*Up to 24 circuit fault locations in 1 hospital power supply
 
*Power supply:DC24V
 
*Communication:CAN
 
*With communication end matching resistor function
Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Parameter
Values
AIL150-4
AIL150-8
Auxiliary power
Voltage
DC24V(±25%)
The maximum power consumption
≤2VA
Monitored system
Rated voltage
0-242VDC
Frequency
45-60HZ
Location signals
Location voltage
<25V
Location current
<1mA
Fault location
the maximum number of loops
4
8
Response time
<2S
Communication
Bus
CAN
Protocol
Custom protocol

Remark:the medical fault locator can locate up to 24 circuits in the same hospital power system

Dimensions and Wirings
Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Solutions and Applications

Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply
name
model
Insulation monitor
AIM-M200
Power module
DR-60-24
Isolation transformer
AITR8000
Current Transformer
AKH-0.66P26
test signal generator
ASG150
insulation fault locator
AIL150-4
centralized remote alarm indicator
AID150
instructions:For the method of the isolation power supply system in the operating room and the intensive care room, please refer to Acrel isolation power supply monitoring system design and application Atlas" and product selection manual.
Medical Insulation Fault Locator Locating for Hospital Isolated Power Supply

About ACREL
Medical Insulation Fault Locator Locating for Hospital Isolated Power SupplyMedical Insulation Fault Locator Locating for Hospital Isolated Power Supply

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company
Number of Employees
40
Year of Establishment
2017-07-25