Customization: | Available |
---|---|
After-sales Service: | 24h Online |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 220.5/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measured parameters |
Total electrical measurement |
Four-quadrant energy,Split phase electricity,Apparent energy,Multi-rate energy | |
Pulse output of energy | Total active ,Total reactive energy pulse output (72 type only has active energy pulses) |
Demand | Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp) |
Extreme value statistics |
Current, line voltage, phase voltage, active power, reactive power and other electrical parameters extreme values of this month and last month (including time stamps) |
Power quality | Unbalance of current, line voltage, phase voltage |
Voltage phase angle, current phase angle | |
Total (odd, even) harmonic content of voltage and current | |
Harmonic content of voltage and current (2-63 times) | |
Interharmonic (included with option S). | |
Flicker (included with S option). | |
Voltage peak coefficient | |
Telephone waveform factor | |
Current K-factor | |
Vector | |
Voltage and current waveform | |
Fundamental voltage and current | |
Fault waveform recording | Record of voltage ramp-up and drop interruptions, inrush currents, etc. (included with S option). |
Event logging | DIDO records, which can record the last 128 DID records |
Alarm logging | The last 128 alarm records can be recorded |
Communication | Modbus - RTU protocol, DL/T 645-2007 statute |
Switching value | 72 Shape: 2 channels of switching input + 2 channels of switching output; 96 Shape: 4 switching inputs + 2 switching outputs |
Base model | Basic function | Optional function | Option Group |
APM510 | 2DI2DO1EP1C | 1. CE (Ethernet Communication/MODBUS-TCP). | 1+5+6+7+8 2+3+4+7+8 5+6+7+8+9 5+6+7+8+10 5+6+7+8+11 5+6+7+8+12 |
2.2C (Extended 2nd Communication). | |||
3.K (2 switch inputs + 2 switch outputs). | |||
4.2M (2ch analog). | |||
5.T (4-channel NTC temperature measurement). | |||
6.L (1 channel leakage). | |||
7.F (Compound Rate). | |||
8.S (0.2S level + fault recording). | |||
9.WF(WiFi Communication) | |||
10.LR(Lora Communication) | |||
11.4G(4G Communication) | |||
12.NB(NB Communication) |
Display | Display method | Dot matrix liquid crystal; Switch between Chinese and English | ||
Resolution | 128*128; | |||
Backlight | White LED; | |||
Visible area | 72 Shape: 38mm*46mm (1.78"/2.3"); 96 Shape: 56mm*60mm (2.46"/3.2"); |
|||
Signal | Electrical network | Three-phase three-wire, three-phase four-wire, see the wiring diagram; | ||
Frequency | 45~65Hz; | |||
Voltage | Rating: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); | |||
Overload: 1.2 times the rating (continuous); 2x rating/1 second; | ||||
Power consumption: < 0.5VA(Every way); | ||||
Current | Ratings: AC 3x 1 (1.2) A, AC 3x5(6)A; | |||
Overload: 1.2 times the rating (continuous); 10x rating/1 second; | ||||
Power consumption: < 0.5VA(Every way); | ||||
Measurement accuracy | Voltage, current | IEC 61557-12 0.2% | ||
Voltage harmonics, current harmonics | IEC 61557-12 1% | |||
Frequency | IEC 61557-12 ±0.02Hz | |||
Active power | IEC 61557-12 0.5% | |||
Reactive power | IEC 61557-12 1% | |||
Active electrical energy | 0.5S class GB/T 17215.321-2008 <=> C class GB/T 17215.321.2021 (0.2S accuracy when S is selected) 0.2S class GB/T 17215.321-2008 <=> D class GB/T 17215.321.2021 (1 accuracy when using the built-in secondary transformer of the instrument) 1class GB/T 17215.321-2008 <=> B class GB/T 17215.321.2021 |
|||
Reactive power | IEC 62053-24 Class 1 | |||
Power quality (only available when S is selected). | Waves recording | 20 waveforms, 10 waves before and after; | ||
Waveform capture | 128 cycle points are stored per waveform; | |||
Switch input | Dry contact input, built-in power supply; Response time: less than 300ms |
|||
Relay output | Contact type: normally open contact; Contact capacity: AC 250V/3A DC 30V/3A; |
|||
Energy pulse output | Output mode: photocoupler pulse with open collector; Pulse constant: 10000imp/kWh (default); |
|||
communication | RS485 interface/Modbus-RTU protocol and DLT645 protocol; RJ45 interface (Ethernet)/Modbus-TCP protocol; Wireless interface |
|||
power supply | Working range: AC 85V~265V; DC100V~350V Power consumption: power consumption≤15VA; |
|||
Safety | Power frequency withstand voltage | The power frequency withstand voltage between the housing and the auxiliary power supply, each input and output terminal group is AC 4kV/1min; The power frequency withstand voltage between the auxiliary power supply and each input terminal and each output terminal group is AC 2kV/1min; The power frequency withstand voltage between the voltage input and other input and output terminal blocks is AC 2kV/1min; The power frequency withstand voltage between the current input and other input and output terminal blocks is AC 2kV/1min; The power frequency withstand voltage between the relay output and other input and output terminal blocks is AC 2kV/1min; The power frequency withstand voltage between the terminal groups of switching input, communication, analog output and pulse output is AC 1kV/1min; |
||
Insulation resistance | Inputs,outputs to the shell>100MΩ; | |||
Electromagnetic compatibility | Complies with IEC 61000 standard (Level 4); | |||
Environment | Operating temperature:-25ºC~+70ºC;Storage temperature:-40ºC~+85ºC; Relative humidity:≤95% without condensation;Altitude:≤2500m; |
|||
Protection Level | Display panel IP54; (Optionally IP65). | |||
Standards | IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-30 |
Environmental Testing-Part 2-1:Tests Test A:Cold IDA Environmental Testing Part 2-2:Tests Test B:Dry heat Environmental Testing Part 2-30:Tests Test Db:Damp heat,cyclic (12+12h) |
||
IEC 61000-4 | Electromagnetic compatibility-Testing and measurement techniques | |||
IEC 61557-12 | Electrical safety in low voltage distribution systems up to 1 000V a.c. and 1 500V d.c -Equipment for testing, measuring or monitoring of protective measures - Part12:Performances measuring and monitoring devices(PMD) | |||
IEC 62053-22 | Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2S and 0.5S) | |||
IEC 62053-24 | Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency (classes 0.5S 1S and 1) |