Home
Product Directory
Electrical & Electronics
Power Transmission & Transformer
Instrument Transformer
Acrel Multifunction Indoor Watt Hour Meter Adl3000-E/CT Digital DIN Rail Kwh Energy Power Meter
| US$107.80 | 2 Pieces (MOQ) |
Port:
Shanghai, China
Production Capacity:
5000
Payment Terms:
T/T
Acrel E-Business (Shanghai) Co., Ltd.
Shanghai, China
Last Login Date:
Nov 06, 2025
Main Products:
Energy Meter, Current Transformer, Hall Effect Current Sensor, Current Transducer, Voltage Sensor, Signal Isolator, Temperature and Humidity Meter, Wireless Temperature Monitoring, Hospital Isolated Power Supply, Motor Protector
Find Similar Products
Product Description
Company Info
Basic Info.
Model NO.
ADL3000-E/CT
Application
Position Sensor
Type
Current Transformer
Phase
Single
Operation Condition
Indoor
Usage
Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
DIN Rail
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Photoelectric Type
Specifications
3 Phase 3 Wires/ 3 Phase 4
Reference Voltag
3*100V/ 3*380V/3*57.7/100V/ 3*220/380V
Voltage Consumption
<10va(Single Phase)
Voltage Impedance
>2m
Accuracy Class
Error About 0.2%
Input Current
3*1(6)a/3*1(6)a(Outlay Transformer)/3*10(80)a/3* 1
Current Consumption
<1va(Single Phase Rated Current)
Power
Activereactive/Apparent Power
Frequency
45 to 65Hz
Switching Output
1 Switching Output, Maximum Allowed Voltage: DC/AC
Switching Input
1 Optocoupler Input,Maximum Allowed Voltage: DC/AC
Interface and Communication
RS485/Modbus
Range of Communication Address
Modbus RTU 1~ 247
Trademark
Acrel
Transport Package
Carton
Specification
60*78*36mm
Origin
Jiangsu, China
HS Code
7201100000
Product Description
Product Description
ADL3000-E is a smart meter designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation. It integrates the measurement of all electrical parameters with the comprehensive electricity metering and management provides
various data on previous 12 months, checks the 31st harmonic content and the total harmonic content, realizes the remote communication and the remote control with switching input and relay output and boasts the alarm output. It is fitted with RS485 communication port and adapted to MODBUS-RTU. ADL3000-E can be used in all kinds of control systems, SCADA systems and energy management systems. All meters meet the related technical requirements of electricity power meter in the IEC62053-21,IEC62053-22 standards.
Detailed Photos
| Voltage | Reference voltage | 3*57.7/100V,3*220/380V,3*100V,3*380V | |||
| Reference frequency | 50Hz | ||||
| Consumption | <10VA(Single phase) | ||||
| Current | Maximum current | 6A,80A | |||
| Starting current | Direct connect:0.004lb Connect via:0.001ln | ||||
| Consumption | <1VA(Single phase rated current) | ||||
| Measurement performance | Accuracy | Class 0.5 | |||
| Standards compliant | IEC 62053-22:2003 | ||||
| Pulse | Pulse width | 80+20ms | |||
| Pulse constant | 400imp/kWh 6400imp/kWh | ||||
| Communication | Interface | RS485 | |||
| Protocol | Mod bus-RTU | ||||
| Temperature range | Work | -25ºC~55ºC | |||
| Storage | -40ºC~70ºC | ||||
| Humidity | ≤95%(No condensation) | ||||
| Altitude | <2000m | ||||
FAQ
Q:I bought a three-phase four-wire meter, can it be wired as three-phase three-wire?A:Yes, press the key to set the meter to three-phase three-wire mode.
Q:What is the difference between ordinary secondary access and -CT (model external transformer)?
A:Ordinary secondary meter could access the ratio XXX/5(1)A of the CTs which could be actual current on site, the -CT model comes with an external transformer will be convenient for installation(It cannot be disassembled, otherwise it will burn the meter). There are CTs available on site to facilitate with No stitch removal.
Q:What are 3*100V,3*57.7/100V,3*380V,3*220/380V?
A:3*100V, 3*57.7/100V are used for high voltage, used in conjunction with voltage transformers, where 3*100V represents 3P3W,3*57.7V/100V represents 3P4W; 3*380V, 3*220V/380V are used for low voltage, direct voltage input, among them3*380V represents 3P3W, 3*220V/380V represents 3P4W.
Q:Can this meter communicate with PLC?
A:Yes, only need PLC to support RS485 interface, Modbus RTU or DL/T645 protocol.
Certifications
Packaging & Shipping
Company Profile
Send your message to this supplier
People who liked this also liked