Customization: | Available |
---|---|
Type: | Signal Isolator |
Output Signal Type: | Analog Output |
Still deciding? Get samples of US$ 63/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
BM-DI DC current transducer / DC signal isolator data sheet
|
||
Input
|
Input current
|
DC 4-20ma,dc 0-20ma
|
Frequency range
|
45Hz-65Hz
|
|
Output
|
Output signal
|
4-20mA,0-20mA,0-5V or 0-10V
|
Output load resistance
|
RL≤600Ω(output current signal)
|
|
RL≥1KΩ(output voltage signal)
|
||
Parameters
|
Power supply
|
AC/DC80-270V DC100-350V or DC24V/DC48V
|
Rated power consumption
|
current,voltage:≤3VA,power:≤4VA
|
|
Accuracy
|
0.50%
|
|
Response time
|
≤400mS
|
|
Temperature drift
|
≤200ppm/ºC
|
|
Isolation intensity
|
(Among input//output//power supply)
|
|
2.0kV/1min, 50Hz
|
||
Insulation resistance
|
≥100MΩ(between input-ouput-power)
|
|
Working temperature
|
-20ºC~+55ºC
|
|
Installation
|
Din rail 35mm
|
Name | Model | Function |
Current signal isolator | BM-DI/IS | transmit dc current signal to 4-20mA output |
BM-DIS/I | passive isolator,standard 4-20mA input,the signal is isolated through 2000V and proportional output is 4-20mA | |
BM-AI/IS | transmit 0-5A AC current to 4-20mA output | |
BM-DI/I | dc current signal is 3-port isolated through 2000V,and output is 4-20mA and ground return can be removed | |
BM-DI/V | dc current signal is 3-port isolated through 2000V,and output signal is 0-5V DC and ground return can be removed | |
Voltage signal isolator | BM-DV/IS | Transmit dc voltage signal to 4-20mA output |
BM-AV/IS | transmit ac 0-450v voltage to 4-20mA output | |
BM-DV/V | dc voltage signal is 3-port isolated through 2000V,and output signal is DC 0-5V and ground return can be removed | |
BM-DV/I | dc voltage signal is 3-port isolated through 2000V,and output signal is 4-20mA and ground return can be removed | |
1 in 2 out signal isolator | BM-DI/II | dc current signal is isolated to 2 output 4-20mA independent signal output |
BM-DV/II | dc voltage signal is isolated to 2 output 4-20mA independent signal output | |
BM-DI/VI | dc current signal is isolated to 2 independent analog signal output,1 channel is 4-20mA and another channel is 0-5V | |
BM-DV/VI | dc voltage signal is isolated to 2 independent analog signal output,1 channel is 4-20mA and another channel is 0-5V | |
Temperature signal isolator | BM-TR/IS | PT100 input,signal is isolated through 2000V voltage and proportional output is 4-20mA |
Resistance signal isolator | BM-R/IS | Supply 4-20mA output and 2000V voltage isolation for standard 2-line resistance signal |
potentiometer signal isolator | BM-VR/IS | Supply 4-20mA output and 2000V voltage isolation for 350Ω-10KΩ potentiometer,and there is surge protection circuit in the module |
Current signal alarm isolator | BM-DI/J | dc current input,dual channel alarm output and dc current off-limt alarm |
Voltage signal alarm isolator | BM-DV/J | dc voltage input,dual channel alarm output and dc voltage off-limt alarm |
Temperature signal alarm isolator | BM-TR/J | pt100 input,dual channel output and temperature off-limit alarm |
Temperature signal isolator | BM-TR/I | PT100 input signal is isolated through 2000v voltage and proportional output is 4-20mA |
BM-TC/I | thermocouple input,proportional output is 4-20mA,it has cold-junction compensation(CJC) and there is surge protection circuit in the module | |
BM-TC/V | thermocouple input,proportional output is 0-5V,it has cold-junction compensation(CJC) and there is surge protection circuit in the module |