Customization: | Available |
---|---|
After-sales Service: | 2 Years |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 30.8/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameters
|
Value
|
|||
Input
|
Connection
|
Single phase-2-wire,3-phase-3-wire,3-phase-4-wire
|
||
Frequency
|
45-65Hz
|
|||
Voltage
|
Rating:single-phase:AC100V,400V
Three-phase:AC3×57.7V/100V(100V),3×220V/380V(400V),3×380V/660V(660V)(96size only) Note:72 profile not suitable for high voltage applications |
|||
Overload:1.2fold rating{continuous):2fold rating for 1second
|
||||
Power consumption:<0.5VA
|
||||
Current
|
Rating:AC IA,5A
|
|||
Overload:1.2 fold rating(continuous);10fold rating for 1second
|
||||
Power consumption:<0.5VA
|
||||
Output
|
Electric energy
|
Output mode:open-collect or photo-coupler pulse
|
||
Pulse constant:10000 imp/kWh(settable),see wiring diagram for details;
|
||||
Communication
|
RS485 port,Modbus-RTU protocol, DLT645 protocol (versions 07 and 97),baud rate1200~38400
|
|||
Function
|
Switching input
|
Dry contact input,built-in power supply;
|
||
Switching output
|
Output mode:Relay normally open contact output
|
|||
Contact capacity:AC250V/3A,DC30V/3A
|
||||
Analog output
|
1-5V,4-20mA
|
|||
Accuracy class
|
Frequency:0.05Hz,Current,Voltage:0.2class,Reactive power:l.0class,Reactive Electric energy:l.0class, active power:0.5class, active electric energy:0.5class,2-31th harmonic measurement:±1%
|
|||
Power supply
|
AC/DC85-265V
|
power consumption≤10VA
|
||
Security
|
Power frequency withstand voltage
|
Between Power supply// Switching Output// Current Input// voltage Input and Transmitting// Communication// Pulse Output//switching input AC2kV 1min;
Between Power supply,switching output,Current Input,voltage Input AC2kV1min; Between Transmitting,Communication,Pulse Output,switching inputAC1kV1min; |
||
Insulation resistance
|
Input,Output end to machine enclosure>100MΩ
|
|||
Environment
|
Temperature
|
work:-25°C~+65°C storage:-40°C~+80°C
|
||
Humidity
|
≤93%RH Non-condensing
|
|||
Altitude
|
≤2500m
|
Meter type
|
Basic function
|
Optional function
|
AMC72-E4/KC AMC72L-E4/KC
|
Three phase voltage, Zero sequence voltage Three phase current, Zero sequence current Three phase active power, Total active power Three phase reactive power, Total reactive power Three phase apparent power, Total apparent power Three phase Power factor, Total power factor Frequency, Voltage phase angle, Voltage and current imbalance, Forward and reverse power Four quadrant energy metering, System time display 1channel RS485 interface/Modbus-RTU protocol and the statute DLT645. |
2DI+2DO+1Ep(K)4DI+2DO(K) Event record(SOE) T2-31th and total harmonics measurement(H ) 1 Channel analog output |
AMC96-E3/KC AMC96L-E3/KC
|
4DI+2DO+1Ep(K)2DI+2DO+1Ep(K) Eventrecord(SOE) 2-31th harmonic measurement(H) 2-channel analog output(M) |
|
AMC96-E4/KC AMC96L-E4/KC
|
||
AMC72E/KC AMC72L-E/KC |
single-phase voltage,single-phase current active power,reactive power, apparent power Power factor Frequency Four quadrant energy metering, System time display 1channel RS485 interface/Modbus-RTU protocol and the statute DLT645. |
DI+2DO+1Ep(K)4DI+2DO(K) Event record(SOE) Total harmonic measurement(H) 1 Channel analog output |
Note:1.DI--Switching input,DO--Switching output,M--Analog output,SOE--Event recording,H--Harmonic measurement,Ep--Electric energy pulse . 2.When the digital tube is displayed, the harmonic data is not displayed, and the data is read only by communication.
3.K is a required function.
4.When Event record(SOE) is selected,Extreme value and maximum demand(D)are available at the same time.
5.The II on the instrument nameplate,representing the second generation product,applies to this specification.
|