Overview
With the rapid development of data centers,the energy consumption of data centers has become more and more prominent. Energy management and power supply and distribution design of data centers have become a hot issue. Efficient and reliable data center power distribution system is an effective way to improve the energy use efficiency of data centers and reduce equipment energy consumption.To realize energy saving of data center,it is necessary to monitor each electrical load first. However,there are many load loops in data center,and traditional measuring instruments cannot meet the requirements of cost,volume,installation,construction and other aspects. Therefore,multi-loop monitoring devices suitable for centralized monitoring of data center are needed.
AMC16Z series DC precise distribution monitoring device is a measurement device designed specifically for data center server power management.The device design exquisite,can for A + B two into line and 96 road for electrical parameters,the input and output parameters of the switch state and the lightning protection device such as real-time monitoring,all alarm threshold measurement channels can be set in A separate,to qualify the limit event trigger system sound and light alarm,immediately on the volume in the traditional instrument,the height of the monitoring circuit integration.
Function&Parameter
Model |
Function description |
AMC16Z-ZD |
Monitor the full-power parameters of the A+B double-channel DC feed circuit,6-way switch status monitoring,2-way alarm output,1-way temperature and humidity detection,1-way RS485 communication,±12V output (only power supply to the feed circuit module supporting Hall sensor). |
AMC16Z-FDK24 |
Monitor the full-power parameters and switching status of A+B double-channel DC outlet 24 and 1-channel RS485 communication. |
AMC16Z-FDK48 |
Monitor the full-power parameters and switching status of A+B double-channel DC off-line 48 sub-lines and 1-channel RS485 communication. |
AMC16Z-KD |
At the dry contact,the switch status of A+B consists of 48 branches and RS485 communication is monitored. |
Technical parameters |
AMC16Z-ZD |
Measured parameters |
Voltage,current,power,electric energy,ambient temperature and humidity |
Rated Voltage |
48VDC,240VDC,336VDC |
Rated Current incoming line circuit |
5V (Hall sensor,powered by AMC16Z-ZD ±12V) |
Switching output |
2 way 3A 250VAC /3A 30VDC |
Switching input |
6 way dry contact |
Communication |
RS485/Modbus-RTU |
Installation |
DIN35mm guide rail or baseplate mounted |
Protection grade |
IP20 |