Basic Info.
After-sales Service
2 Years
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Voltage Rated Value
3*220/380VAC
Current
5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA
Auxiliary Power Supply
Triggered Upon Receipt of Request Signal
Temperature Detection
-20-150 Degree
Product Description
Acrel AMB Series Intelligent Busway AC Monitoring Meter
Product Description
AMB intelligent bus AC monitoring device is a new development to cater for smart power bus bar. It consists of a feeding detection module and a tapping detection module and integrates functions of conventional power measurements, electricity monitoring, consumption assessment and control. It also boasts the online alarm
function and enables the independent off-line operation. It monitors the bus bar interface temperature in real time. By virtue of 2 RJ45 communication ports (1 in and 1 out) and MODBUS-RTU protocol, it is easy and reliable to upload the monitoring data to the touch screen of the main controller for centralized monitoring, ensuring safe and reliable operation of the system. The smart bus bar monitor has several benefits such as flexible and convenient wiring so that it is a good substitution of the traditional centralized array cabinet.
Product Selection
Model | Standard functions | Optional functions |
AMB100-A | (1) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity, maximum demand measurement, neutral current, potential difference measurement between the null line and the ground line, 2 digital inputs, 2 digital outputs | /W(LORA) |
AMB100-A-P1 | (2) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity,maximum demand measurement, neutral current measurement, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply | |
AMB110-A | (1) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity,maximum demand measurement, neutral current measurement, potential difference measurement between the null line and the ground line, 2 digital inputs, 2 digital outputs | |
AMB110-A-P1 | (2) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity, maximum demand measurement, neutral current measurement, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply | |
AMB120 | 8-way temperature | |
AMB120-J | 8-way temperature, 1 switch output | |
AMB10 | Monitor;the front network port:AMB10(F),the rear network port:AMB10(B&DZ),can automatically display the voltage and current parameters | |
AMB10L-72 | Optional rear network port or bottom network port, can automatically cycle display voltage, current, temperature and other parameters | |
AMB20 | AMB20-1:accessory,used with AMB100/AMB110 for network port to network port transfer of intelligent bus staring box and plug-in box AMB20-2:accessory,used with AMB100/AMB110 for RS485 port to network port transfer of intelligent bus staring box and plug-in box AMB20-3: accessory, used with AMB100/AMB110, used for network port-to-network port transfer of intelligent bus head box and plug-in box. AMB20-4: Accessory, used with AMB100/AMB110, used for RS485 port-to-network port conversion of intelligent bus head box and plug-in box. | |
Note 1. AMB:bus bar series; 100:for feeding cabinet; 110: for tapping cabinet; 120:for temperature detection; A: for alternating-current system; P1:discrete auxiliary power supplyNote 2. Optional AMB10, AMB10L-72 display, automatic cycle display voltage, current parameters.Note 3. For optional LORA function, an external magnetic antenna is equipped. The standard length is 2 m.Note 4. For temperature sensors, there are two round-hole variants, namely 12mm-hole variant and 8mm-hole variant, and one 6mm-cylindrical variant. Each variant includes yellow, green, red and black sensors.
Product Parameters
AMB100-A(-W)/AMB110-A(-W)
Measured parameters | Voltage, current, frequency, active power, inactive power, power factor, active energy, inactive energy, 2nd-63rd harmonic, temperature, leakage |
Voltage | Rated value | 3x220/380VAC |
Range | ±20% |
Overloading | 1.2 times than the rated voltage value continuously or 2 times than the rated voltage value instantaneously per second |
Current | CT | AMB100-A:5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA AMB110-A:100A/20mA |
Range | 1%-120% |
Overloading | 1.2 times than the rated current value continuously or 10 times than the rated current value instantaneously per second |
Input frequency | 45-65Hz |
Measurement accuracy | Voltage/current:grade 0.2; active power/energy:grade 0.5; inactive power/energy:grade 1; temperature:±1ºC |
Auxiliary power supply | AMB100/110-A(/W):triggered upon receipt of request signal AMB100/110-A(/W)-P1:follow the bus bar voltage |
functions | Temperature detection | -20-150ºC |
Leakage | 0-1A |
Digital input | 2 dry-contact inputs |
Digital output | 2 relay outputs; contact capacity:3A/30VDC, 3A/250VAC |
Communication | Via RS485/Modbus-RTU or LORA antenna |
Installation | Use DIN35mm rail |
Protection | IP20 |
Pollution level | 2 |
Environment | Temperature/ humidity/ altitude | Working temperature:-20-60ºC Storage temperature:-25-70ºC Relative humidity:≤93% Altitude:≤2500m |
Safety | Insulation | The minimum insulation resistance between all terminals and conductive components of the shell is 100MΩ. |
Withstanding voltage | When a voltage of 2kV AC is applied between the voltage/ current input, relay output, RS485 port, auxiliary power supply and digital inputs, the leakage shall be less than 2mA and no breakdown or flashover shall occur in 1min.. |
Electromagnetic immunity | Electrostatic discharge immunity | Class 4 |
Radio frequency electromagnetic immunity | Class 3 |
Transient burst immunity | Class 4 |
Surge immunity | Class 4 |
Dimension
Company Profile
Address:
No. 253, Jiading district, Shanghai, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics, Instruments & Meters
Management System Certification:
ISO 9001, ISO 9000
Company Introduction:
Acrel Co., Ltd. [stock code: 300286. SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.