• Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device
  • Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device
  • Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device
  • Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device
  • Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device
  • Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Warranty: 2 Years
Installation: Direct Connected
Usage: Multi-Functional Energy Meter
Electric Equipment: Three-phase Four-wire
Theory: Electronic Meter
Power Meter Connection: Terminal
Samples:
US$ 165.9/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Certifications
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
AMC100-FAK48
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
CE
Customized
Non-Customized
Model Number
Amc100-Fak48
Accuracy Class
0.5
Operating Temperature
-15~55centigrade
Interface
RS485
Communication
Modbus RTU
Frequency
45-65Hz
Relative Humidity
<93%
Rated Voltage
220VAC
Rated Current
50mA
ODM
Support
Transport Package
Carton
Specification
180*90mm
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
10000pieces/Month

Product Description

Product Description

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Acrel AMC100 series AC precision power distribution monitoring device is a measuring device designed specifically for power management of data center servers. The device is compact in design and can monitor the full electrical parameters, input and output switches and the status of the lightning arrester of A+B two incoming lines and 192 outgoing lines in real time. The alarm thresholds of all measurement channels can be set individually, and the outgoing line The limited event immediately triggers the system's sound and light alarms, and the high integration of the monitoring loop is realized in the volume of the traditional instrument.

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring DeviceAmc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

 

Product Parameters

 
Model Function Description
AMC100-ZA Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications
AMC100-FAK30 Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FAK48 Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FA30 Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-FA48 Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication
AMC100-KA30 Wet contact, monitor the  switching status of  30 branches A+B, 1 RS485 communication
AMC100-KA48 Wet contact, monitor the  switching status of  48 branches A+B, 1 RS485 communication
AMC100-KD30 Dry contact, monitor the  switching status of  30 branches A+B, 1 RS485 communication
AMC100-KD48 Dry contact, monitor the  switching status of  48 branches A+B, 1 RS485 communication
AMC100-FT30 1 way RS485 communication, 30 way temperature measurement
AMC100-FT48 1 way RS485 communication, 48 way temperature measurement

 

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Installation Instructions

 

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device
Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Certifications

 

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Company Profile

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

Packaging & Shipping

Amc16z-Fak48 Data Center Outgoing Line 48 Circuits Energy Meter Precision Power Distribution Monitoring Device

FAQ

Q:Where is your company located?
A:Our headquarter is in Shanghai, our factory locates in Jiangyin,Jiangsu Province,China.
It takes about 1 hour by car from Shanghai Hongqiao International Airport to our factory

Q:What's your lead time?
A:Sample time 1-3days,mass production 10~20days for order more than 500pcs

Q:Payment terms?
A:Usually,TT,credit card,western union,in cash and so on.You can also choose to pay 30% as deposit and the balance before shipment.

Q:What certifications do you have ?
A:We have ISO9001,IEC,CE and so on.


Q:Can other logo be put on your products(OEM)?
A:Yes,but MOQ for OEM will be at least 100pcs.We also need you provide logo Ai Format or EPS.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now