Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 2 Years
Still deciding? Get samples of US$ 50/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (24)
  • Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
  • Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
  • Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
  • Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
  • Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
  • Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
Find Similar Products
  • Overview
  • Product Description
  • Function & Optional Function
  • Dimension drawing
  • Connection Method
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16-DETT
Display
Digital
Installation
Indirect Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter
Electric Equipment
DC Energy Meter
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Voltage
-48VDC
Current
5V (Hall Sensor Output)
Communication
RS485(Modbus-RTU)
Baud Rate
1200BPS - 9600BPS
Accuracy
1 Class
Power Supply
-40V~-60VDC
Hall Sensor Power Supply
+12V/100mA, -12V/50mA
Transport Package
Packing
Specification
89*87*52mm
Trademark
Acrel
Origin
China
HS Code
9028309000
Production Capacity
5000/Years

Packaging & Delivery

Package Size
20.00cm * 25.00cm * 20.00cm
Package Gross Weight
2.000kg
Lead Time
10 days (1 - 50 Pieces)
To be negotiated ( > 50 Pieces)

Product Description

Acrel AMC16-DETT DC Energy Meter with 6 Measuring Channels & RS485 Communication
for Base Station

Product Description

 
Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station

       
       AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure 6 circuits DC energy, and supply working  current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software. have the functions of telemetering,teleindication,teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing , data interaction. The module can measure the DC power consumption of multiple circuits separately, providing detail datas for base station.

Function & Optional Function

Basic function
Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED indicator display;
Metering function
U,I,P,Q,S,PF,F
Alarm function
DC voltage output low alarm; DC voltage output high alarm; one power down alarm; module voltage loss alarm; metering branch error alarm; internal program error alarm; clock error alarm; memory failure alarm; AC input power failure alarm
Communication
Single channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.
Communication protocol: standard or custmized
Hall sensor power supply
Power supply output:+12V/100mA, -12V/50mA
 

Dimension drawing

Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station

Connection Method

 AMC16-DETT measure 6 DC circuits (connect via hall sensor)
Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station
 

Installation Instructions

Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station

Company Profile

Acrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base StationAcrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base StationAcrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base StationAcrel Amc16-Dett DC Energy Meter with 6 Measuring Channels & RS485 Communication for Base Station















 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier