• Acrel Apm510-CE Network Power Meter with Ethernet Communication
  • Acrel Apm510-CE Network Power Meter with Ethernet Communication
  • Acrel Apm510-CE Network Power Meter with Ethernet Communication
  • Acrel Apm510-CE Network Power Meter with Ethernet Communication
  • Acrel Apm510-CE Network Power Meter with Ethernet Communication

Acrel Apm510-CE Network Power Meter with Ethernet Communication

After-sales Service: 24h Online
Warranty: 2 Years
Display: Digital
Samples:
US$ 248/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Acrel Apm510-CE Network Power Meter with Ethernet Communication pictures & photos
Acrel Apm510-CE Network Power Meter with Ethernet Communication
US $248 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
APM510-CE
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, CE
Customized
Customized
Measured Parameters
Total Electrical Measurement
Communication
Modbus - RTU Protocol, Dl/T 645-2007 Statute
Event Logging
Dido Records, Which Can Record The Last 128 Did Re
Ratings
AC 3X 1 (1.2) a, AC 3X5(6)a
Transport Package
Carton
Trademark
Acrel
Origin
China
HS Code
9028301400

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 12.00cm
Package Gross Weight
1.000kg
Lead Time
2 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

APM5 series network power meter

1.Overview
APM5 series network power meter (hereinafter referred to as the meter) is designed according to IEC international standards, with full power measurement, power statistics, power quality analysis (including harmonics, interharmonics, flicker), fault recording function (including voltage temporary rise and fall interrupt, inrush current and other records), event recording function and network communication and other functions. It is mainly used for comprehensive monitoring of power supply quality in the power grid. This series of meters is equipped with feature-rich DI/DO modules, AO modules, wireless communication modules, leakage temperature measurement modules, which can flexibly realize the full electrical circuit Power measurement and switching status monitoring. 
Product model specifications and functions

Acrel Apm510-CE Network Power Meter with Ethernet Communication
Note:1,When the meter is connected by 5A/1.25mA as the two-time mutual inductance method, the meter's own secondary-side transformer should be kept at a distance from the on-site primary-side transformer to avoid out-of-line interference. 

Type and function
Measured
parameters
Total electrical measurement
Four-quadrant energy,Split phase electricity,Apparent energy,Multi-rate energy
Pulse output of  energy Total active ,Total reactive energy pulse output (72 type only has active energy pulses)
Demand Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)
Extreme
value statistics
Current, line voltage, phase voltage, active power, reactive power and other electrical parameters extreme values of this month and last month (including time stamps)
Power quality Unbalance of current, line voltage, phase voltage
Voltage phase angle, current phase angle
Total (odd, even) harmonic content of voltage and current
Harmonic content of voltage and current (2-63 times)
Interharmonic (included with option S).
Flicker (included with S option).
Voltage peak coefficient
Telephone waveform factor
Current K-factor
Vector
Voltage and current waveform
Fundamental voltage and current
Fault waveform recording Record of voltage ramp-up and drop interruptions, inrush currents, etc. (included with S option).
Event logging DIDO records, which can record the last 128 DID records
Alarm logging The last 128 alarm records can be recorded
Communication Modbus - RTU protocol, DL/T 645-2007 statute
Switching value 72 Shape: 2 channels of switching input + 2 channels of switching output;
96 Shape: 4 switching inputs + 2 switching outputs
Function selection
Base model Basic function Optional function Option Group
APM510 2DI2DO1EP1C 1. CE (Ethernet Communication/MODBUS-TCP). 1+5+6+7+8
2+3+4+7+8
5+6+7+8+9
5+6+7+8+10
5+6+7+8+11
5+6+7+8+12
2.2C (Extended 2nd Communication).
3.K (2 switch inputs + 2 switch outputs).
4.2M (2ch analog).
5.T (4-channel NTC temperature measurement).
6.L (1 channel leakage).
7.F (Compound Rate).
8.S (0.2S level + fault recording).
9.WF(WiFi Communication)
10.LR(Lora Communication)
11.4G(4G Communication)
12.NB(NB Communication)
Technical parameters
 
Display Display method Dot matrix liquid crystal;  Switch between Chinese and English
Resolution 128*128;
Backlight White LED;
Visible area 72 Shape: 38mm*46mm (1.78"/2.3");
96 Shape: 56mm*60mm (2.46"/3.2");
Signal Electrical network Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency 45~65Hz;
Voltage Rating: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only);
Overload: 1.2 times the rating (continuous); 2x rating/1 second;
Power consumption: < 0.5VA(Every way);
Current Ratings: AC 3x 1 (1.2) A, AC 3x5(6)A;
Overload: 1.2 times the rating (continuous); 10x rating/1 second;
Power consumption: < 0.5VA(Every way);
Measurement accuracy Voltage, current IEC 61557-12   0.2%
Voltage harmonics, current harmonics IEC 61557-12   1%
Frequency IEC 61557-12   ±0.02Hz 
Active power IEC 61557-12   0.5%
Reactive power IEC 61557-12   1% 
Active electrical energy 0.5S class  GB/T 17215.321-2008 <=> C class  GB/T 17215.321.2021

(0.2S accuracy when S is selected)
0.2S class GB/T 17215.321-2008 <=>  D class GB/T 17215.321.2021

(1 accuracy when using the built-in secondary transformer of the instrument)
1class  GB/T 17215.321-2008  <=> B class    GB/T 17215.321.2021
Reactive power IEC 62053-24  Class 1
Power quality (only available when S is selected). Waves recording 20 waveforms, 10 waves before and after;
Waveform capture 128 cycle points are stored per waveform;
Switch input Dry contact input, built-in power supply;
Response time: less than 300ms
Relay output Contact type: normally open contact;
Contact capacity: AC 250V/3A DC 30V/3A;
Energy pulse output Output mode: photocoupler pulse with open collector;
Pulse constant: 10000imp/kWh (default);
communication RS485 interface/Modbus-RTU protocol and DLT645 protocol;
RJ45 interface (Ethernet)/Modbus-TCP protocol;
Wireless interface
power supply Working range: AC 85V~265V;  DC100V~350V
Power consumption: power consumption≤15VA;
Safety  Power frequency withstand voltage The power frequency withstand voltage between the housing and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input terminal and each output terminal group is AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the terminal groups of switching input, communication, analog output and pulse output is AC 1kV/1min;
Insulation resistance Inputs,outputs to the shell>100MΩ;
Electromagnetic compatibility Complies with IEC 61000 standard (Level 4);
Environment Operating temperature:-25ºC~+70ºC;Storage temperature:-40ºC~+85ºC;
Relative humidity:≤95% without condensation;Altitude:≤2500m;
Protection Level Display panel IP54; (Optionally IP65).
Standards IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Environmental Testing Part 2-2:Tests Test B:Dry heat
Environmental Testing Part 2-30:Tests Test Db:Damp heat,cyclic (12+12h)
IEC 61000-4 Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12 Electrical safety in low voltage distribution systems up to 1 000V a.c. and 1 500V d.c -Equipment for testing, measuring or monitoring of protective measures - Part12:Performances measuring and monitoring devices(PMD)
IEC 62053-22 Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2S and 0.5S)
IEC 62053-24 Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency (classes 0.5S 1S and 1)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Acrel Apm510-CE Network Power Meter with Ethernet Communication pictures & photos
Acrel Apm510-CE Network Power Meter with Ethernet Communication
US $248 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
40
Year of Establishment
2017-07-25