Acrel APM520 three phase multifunction power meter
True RMS Measurements
Unbalance & Phase Angles
True RMS Measurements
Unbalance & Phase Angles
Demands and Multi-Tariff energy
Max/Min Log with Timestamp
Total harmonics, odd,even harmonics
Accuracy: 0.2s
APM series power meters are designed according to IEC standards.
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module,event recording (SOE) module with T-Flash (TF) card, network communication module, can achieve full power measurement of electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize high-speed data transmission and networking function.
Installation: Panel mounted
Frequency: Range: 45-65Hz
Relay: 3A/AC250V, 3A/DC30V
Dimension (L*W*H):
Panel size (L×W): 96*96mm
Cut-out size (L×W): 92*92mm
Auxiliary Power Supply:
AC/DC 85V~265V or AC/DC 115~415V
Accuracy
Voltage,current and power: Class 0.5S
Active power: Class 0.5S; Reactive power: Class 2
Harmonic:1%(2~42nd),2%(24~63rd)
Pulse Output
Output mode: Optocoupler pulse with open collector;
Pulse constant: 4000 (5A),8000 (1A) imp/kWh;
Consumption
Voltage,current: Power consumption: <0.5VA;
Auxiliary power supply: Power consumption ≤15VA
Starting Current
0.1%
Technical Parameters |
Index |
|||
Signal |
Electrical network |
Three-phase three-wire, three-phase four-wire, see the wiring diagram; |
||
Frequency |
45~65Hz; |
|||
Voltage |
Rated value:AC 100V,110V,400V,690V; |
|||
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second; |
||||
Power consumption: < 0.5VA (per channel); |
||||
Current |
Rated value: AC 1A, 5A, support 4 mm2 line access; |
|||
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second; |
||||
Power consumption: < 0.5VA (per channel); |
||||
Measurement accuracy |
Voltage,current and power |
class 0.5s/class 0.2s (APM800,APM810/APM801) |
||
Active power |
class 0.5s/class 0.2s (APM800,APM810/APM801) |
|||
Reactive power |
class 2 |
|||
Harmonic |
1%(2rd~42nd),2%(43rd~63rd) |
|||
Switch inputs |
Dry contact inputs, built-in power supply; |
|||
Relay outputs |
Contact type: open contact in main part, changeover contact in module; Contact capacity:AC 250V/3A DC 30V/3A; |
|||
Pulse output of energy |
Output mode: Optocoupler pulse with open collector; Pulse constant:4000(5A),8000(1A) imp/kWh; |
|||
Analog outputs |
DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω; |
|||
Analog inputs |
DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V iutput, accuracy class 0.5% |
|||
Storage card |
Standard Capacity:4G,TF Card Up to 32G Capacity; |
|||
Communication |
RS485 interface/Modbus-RTU protocol and DLT645 protocol Profibus-DP interface/Profibus-DP protocol; RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols; |
|||
Power supply |
Working range: AC/DC 85V~265V or AC/DC 115~415V(P2); Power consumption: Power consumption of the main part ≤ 15VA; |
|||
Safety |
Power frequency withstand voltage |
The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min; The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min; The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min; |
||
Insulation resistance |
Inputs,outputs to the shell>100MΩ; |
|||
Electromagnetic compatibility |
Meet IEC 61000 standard (Level 4); |
|||
Protection level |
Display panel IP52 |
|||
Environment |
Operating temperature: -20 °C ~ +65 °C; Storage temperature: -20°C~+70°C; Relative humidity: ≤95% without condensation; Altitude: ≤2500m; |
|||
Standards |
IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-30 |
Environmental Testing-Part 2-1:Tests Test A:Cold IDA Part 2-1:Tests Test B:Dry heat Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h) |
||
IEC 61000-4 |
Electromagnetic compatibility-Testing and measurement techniques |
|||
IEC 61557-12 |
Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c -Equipment for testing,measuring or monitoring of protective measures- Part12: Performances measuring and monitoring devices(PMD) |
|||
IEC 62053-22 |
Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s) |
Q: What's the storage capacity, storage format and data storage interval of SD card?
A: The meter is equiped with standard 4G SD card while saving the data of electrical parameter, energy, event, SOE, alarm. Also, the setting of storage interval could be changed. (1 min interval for electrical parameter and 1 hour interval for energy)
Q: How should I select the expanded modules of APM8xx?
A: Our users can select 3 of the optional modules at will even repeatly except for communication module. Also, the order of module installation could be random
Q: The features of APM8xx?
A: Except for wave record and SD card storage function, 0.2S measuring accuracy can also be a option. Besides, APM8xx can serve as reverse display meter (which means 3-phase electrical parameters measuring plus 8-channel reverse display) Also, users can measure the data through browser by using Ethernet auto WEB.
Q: As for the auxiliary power supply of APM8xx?
A: AC/DC 85~265V or 115~415V is both optional. Also, 380V line voltage can also serve as power supply.