Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Still deciding? Get samples of US$ 90/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (24)
  • Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
  • Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
  • Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
  • Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
  • Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
  • Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
Find Similar Products
  • Overview
  • Product Description
  • Product Selection
  • Product Parameters
  • Dimension
  • Company Profile
Overview

Basic Info.

Model NO.
AMB100-A-P1
Display
Digital
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Customized
Customized
Voltage Rated Value
3*220/380VAC
Current
5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA
Input Frequency
45-65Hz
Auxiliary Power Supply
Triggered Upon Receipt of Request Signal
Temperature Detection
-20-150 Degree
Protection
IP20
Transport Package
Carton
Specification
70*36*50mm
Trademark
ACREL
Origin
Mainland China
HS Code
9028301300
Production Capacity
1000PCS/Per Month

Packaging & Delivery

Package Size
26.50cm * 17.00cm * 17.00cm
Package Gross Weight
0.750kg
Lead Time
15 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Acrel AMB Series Intelligent Busway AC Monitoring Meter
Product Description
AMB intelligent bus AC monitoring device is a new development to cater for smart power bus bar. It consists of a feeding detection module and a tapping detection module and integrates functions of conventional power measurements, electricity monitoring, consumption assessment and control. It also boasts the online alarm
function and enables the independent off-line operation. It monitors the bus bar interface temperature in real time. By virtue of 2 RJ45 communication ports (1 in and 1 out) and MODBUS-RTU protocol, it is easy and reliable to upload the monitoring data to the touch screen of the main controller for centralized monitoring, ensuring safe and reliable operation of the system. The smart bus bar monitor has several benefits such as flexible and convenient wiring so that it is a good substitution of the traditional centralized array cabinet.
Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
 
Product Selection
Model Standard functions Optional functions
AMB100-A (1) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity, maximum demand measurement, neutral current, potential difference measurement between the null line and the ground line, 2 digital inputs, 2 digital outputs /W(LORA)
AMB100-A-P1 (2) Full electrical measurements of three-phase AC circuit, 2nd to 63rd  harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity,maximum demand measurement, neutral current measurement, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply  
AMB110-A (1) Full electrical measurements of three-phase AC circuit, 2nd to 63rd  harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity,maximum demand measurement, neutral current measurement, potential difference measurement between the null line and the ground line, 2 digital inputs, 2 digital outputs  
AMB110-A-P1 (2) Full electrical measurements of three-phase AC circuit, 2nd to 63rd  harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity, maximum demand measurement, neutral current measurement, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply  
AMB120 8-way temperature  
AMB120-J 8-way temperature, 1 switch output  
AMB10 Monitor;the front network port:AMB10(F),the rear network port:AMB10(B&DZ),can automatically display the voltage and current parameters  
AMB10L-72 Optional rear network port or bottom network port, can automatically cycle display voltage, current, temperature and other parameters  
AMB20 AMB20-1:accessory,used with AMB100/AMB110 for network port to network port transfer of intelligent bus staring box and plug-in box
AMB20-2:accessory,used with AMB100/AMB110 for RS485 port to network port transfer of intelligent bus staring box and plug-in box
AMB20-3: accessory, used with AMB100/AMB110, used for network port-to-network port transfer of intelligent bus head box and plug-in box.
AMB20-4: Accessory, used with AMB100/AMB110, used for RS485 port-to-network port conversion of intelligent bus head box and plug-in box.
 
Note 1. AMB:bus bar series; 100:for feeding cabinet; 110: for tapping cabinet; 120:for temperature detection; A: for alternating-current system; P1:discrete auxiliary power supply
Note 2. Optional AMB10, AMB10L-72 display, automatic cycle display voltage, current parameters.
Note 3. For optional LORA function, an external magnetic antenna is equipped. The standard length is 2 m.
Note 4. For temperature sensors, there are two round-hole variants, namely 12mm-hole variant and 8mm-hole variant, and one 6mm-cylindrical variant. Each variant includes yellow, green, red and black sensors.
Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
Product Parameters

AMB100-A(-W)/AMB110-A(-W)

Measured parameters Voltage, current, frequency, active power, inactive power, power factor, active energy, inactive energy, 2nd-63rd harmonic, temperature, leakage
Voltage Rated value 3x220/380VAC
Range ±20%
Overloading 1.2 times than the rated voltage value continuously or 2 times than the rated voltage value instantaneously per second
Current CT AMB100-A:5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA
AMB110-A:100A/20mA
Range 1%-120%
Overloading 1.2 times than the rated current value continuously or 10 times than the rated current value instantaneously per second
Input frequency 45-65Hz
Measurement accuracy Voltage/current:grade 0.2; active power/energy:grade 0.5; inactive power/energy:grade 1; temperature:±1ºC
Auxiliary power supply AMB100/110-A(/W):triggered upon receipt of request signal
AMB100/110-A(/W)-P1:follow the bus bar voltage
functions Temperature detection -20-150ºC
Leakage 0-1A
Digital input 2 dry-contact inputs
Digital output 2 relay outputs; contact capacity:3A/30VDC, 3A/250VAC
Communication Via RS485/Modbus-RTU or LORA antenna
Installation Use DIN35mm rail
Protection IP20
Pollution level 2
Environment Temperature/ humidity/ altitude Working temperature:-20-60ºC
Storage temperature:-25-70ºC
Relative humidity:93%
Altitude:2500m
Safety Insulation The minimum insulation resistance between all terminals and conductive components of the shell is 100MΩ.
Withstanding voltage When a voltage of 2kV AC is applied between the voltage/ current input, relay output, RS485 port, auxiliary power supply and digital inputs, the leakage shall be less than 2mA and no breakdown or flashover shall occur in 1min..
Electromagnetic immunity Electrostatic discharge immunity Class 4
Radio frequency electromagnetic immunity Class 3
Transient burst immunity Class 4
Surge immunity Class 4
Dimension

Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply

Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply
Company Profile

Acrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power SupplyAcrel Amb100-a-P1 Intelligent Busway AC Monitoring Meter for Busbar with Discrete Auxiliary Power Supply

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier