• UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
  • UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
  • UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
  • UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
  • UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
  • UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement

UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement

After-sales Service: 2 Years
Warranty: 2 Years
Display: Digital
Samples:
US$ 103/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement pictures & photos
UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
US $103 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Wiring Diagram
  • Dimensions(Unit:mm)
  • Installation
  • Technical Parameters
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
DJSF1352-RN
Installation
Indirect Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Single-phase
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Power Meter
Certification
RoHS, CE
Customized
Non-Customized
Input Current
5V by Hall Sensor Access
Input Voltage
DC 1000V Max
Accuracy
Class 0.5
Power Supply
AC/DC 85-265V
Communication
RS485
Transport Package
Paper
Specification
2kgs
Trademark
Acrel
Origin
Jiangsu China
HS Code
9028301400
Production Capacity
99999pieces/Year

Packaging & Delivery

Package Size
30.00cm * 28.00cm * 25.00cm
Package Gross Weight
2.000kg

Product Description

Product Description

Measurement: kWh, kVarh, Power, Current, Voltage and etc
Current Rating: Shunt 0-75mV; Hall sensor 0-20mA,4-20mA,0-5 V,0-10V
Voltage Rating: 0~1000V DC
Application: DC Battery; Charging Pile; Solar PV and etc
Communication: DL/T645-2007 Protocol, MODBUS-RTU Protocol
Power Supply: 85~265V AC/DC; 24V(±10%) DC; 48V(±10%) DC
Pulse Input: One Second pulse output, one electric energy pulse output
Display: 8 Digital Segment type LCD
Dimension: 72*71*87.8mm (L*W*H)
Installation: 35mm DIN Rail
Standard&Certificate: CE

Detailed Photos
UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
 SOE Event Record
 Infrared Communication
 BI-Direction Active Power Measuring
 Multi-Tariff Function
 8 Digital LCD Display
 Maximum Voltage Output 1000V
 
Wiring Diagram

UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement

Wiring with Shunt

UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement

Wiring with Hall Sensor

 

Dimensions(Unit:mm)
UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
Installation

UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
 

Technical Parameters
Technical parameters Index
Input Nominal value Voltage input range Current input
DC 0-1000V
See the physical wiring diagram
Shunt:0-75mV;
Hall sensor:0-20mA,4-20mA,0-5V,0-10V and so on.
Overload 1.2 times rated (continuous); 2 times rated/1 second;
Power consumption Voltage: ≤0.2VA, current ≤0.1VA
Accuracy class Class 1 or Class 0.5
Function Display 8-bit segment LCD screen (LCD)
Communication Interface RS485(two options)
Communication protocol Modbus-RTU,DL/T 645-2007
Switch Switch output 2 Relay outputs, 2A/30VDC or 2A/250VAC
Switch input 2 dry contact inputs
Pulse output A second pulse output, a energy pulse output
See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWH
Power Supply Voltage range AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
Power consumption ≤ 3W
Power frequency withstand voltage Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min
Power supply // Relay output // Voltage input // Current input 3kV/1min
Pulse output // Communication interface // Switch input 2kV/1min
Impulse withstand voltage ±6KV
Insulation resistance ≥ 40MΩ
Average barrier-free working hours ≥50000h
Environment Temperature Normal operating temperature: -25 °C ~ +65 °C; Limit working temperature: -40 °C ~ +70 °C;
Storage temperature: -40ºC~+80ºC
Humidity ≤93%RH, no condensation, no corrosive gas
Altitude ≤2500m
Company Profile

UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement

UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement

FAQ

Q:Where is your company located?
 
A:Our headquarter is in Shanghai, our factory locates in Jiangyin,Jiangsu Province,China.It takes about 1 hour by car from Shanghai Hongqiao International Airport to our factory. As it is low labor cost here in Jiangsu,we can offer a better price with high quality.

 
A:Our headquarter is in Shanghai, our factory locates in Jiangyin,Jiangsu Province,China.It takes about 1 hour by car from Shanghai Hongqiao International Airport to our factory. As it is low labor cost here in Jiangsu,we can offer a better price with high quality.
 
Q:What's your lead time?
 
A:Sample time 1-3days,mass production 10~20days for order more than 500pcs
 
Q:Payment terms?
 
A:Usually,TT,credit card,western union,in cash and so on.You can also choose to pay 30% as deposit and the balance before shipment or against copy of B/L if the order is large.
 
Q:Can other logo be put on your products(ODM)?

A:Yes,but MOQ for ODM will be at least 5pcs.We also need you provide logo Ai Format or EPS.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement pictures & photos
UL Certificate Dual Loop Monitoring DC Energy Meter 1000V DC Voltage Measurement
US $103 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
40
Year of Establishment
2017-07-25