Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2017-07-25
  • Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
  • Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
  • Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
  • Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
  • Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
  • Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
Find Similar Products
  • Overview
  • Product Description
  • Function
  • Product Parameters
  • Appearance
  • Wiring
  • Installation Instructions
  • Networking
  • FAQ
Overview

Basic Info.

Model NO.
ADL400N/CT
Installation
Direct Connected
Usage
Multi-Functional Energy Meter
Electric Equipment
Three-phase Three-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
CE, Eac, MID
Customized
Customized
Rated Current
80A/120A/200A/300A Direct Access
Rated Voltage
AC 220V/380V, AC 230V/400V
Input Voltage
Less Than 20%
Power Consumption
<0.2va
Accuracy Class
Error Less Than 0.5%
Input Current
80A, 120A, 200A, 300A,3*80A,, 3*120A
Grid Frequency
45~65Hz, Error Less Than 0.5%
Response Rate
Less Than 1s (Electrical Energy)
Electric Energy
Active Energy(Class B),Reactive Energy (Class 2)
Communication
RS485(Modbus-RTU)
Transport Package
Carton
Specification
90*45*65mm
Trademark
ACREL
Origin
Mainland China
HS Code
9028301300
Production Capacity
20000

Product Description


ADL400N Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
Product Description
 

ADL series DIN-rail mounted multi functional electric energy meter is an intelligent instrument mainly designed for new energy power generation systems such as photovoltaic grid-connected system, micro inverter system, energy storage system, AC coupling system, etc. The product has the advantages of high precision, small volume, high respondent speed and convenient installation. The product has the features of sampling, metering and monitoring power parameters,communicating with an inverter or an energy management system (EMS), realizing the functions of preventing reverse flow, regulating power generation, charging and discharging batteries according to real-time power and accumulated electric energy, and realizing bidirectional metering and household distributed photovoltaic energy management.

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
Function
Function Descriptions ADL200N-CT ADL400N-CT
Electric energy metering Active energy metering (forward and reverse) Y Y
Reactive energy metering (forward and reverse) Y Y
Split-phase energy N Y
Electric quantity measurement U, I Y Y
P, Q, S, PF, F Y Y
LCD display Segmented LCD display Y Y
Key programming ommunication, transformation ratio and other parameters can be programmable by the key N Y
Pulse output Active pulse output Y Y
LED alarm Operation instructions N Y
Communication RS485:Modbus RTU Y Y
 

 

Product Parameters

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

Item Performance Parameters
Model Series ADL200N-CT ADL400N-CT
Measurement Grid Single-phase Three-phase four-wire, three-phase three-wire, single-phase three-wire
Voltage Rated voltage 230V 3×220/380V,3×230/400V,3×277/480V
Input Range ±20%
Overload 1.2 times rating (continuous) ,2 times the rating for 1 second
Power consumption <0.2VA
Accuracy class Error ±0.5%
Current Input current 80A, 120A, 200A, 300A 3×80A, 3×120A, 3×200A, 3×300A
Overload 1.2 times rating (continuous) ,2 times the rating for 1 second
Power consumption <0.2VA
Accuracy class Error ±0.5%
Power Active, reactive, apparent power, error ±0.5℅
Grid frequency 45~65Hz, error ±0.5%
Response rate ≤100ms (voltage, current, power)
≤1s (electrical energy)
Metering Electric energy Active energy :Class B (split current transformer)Reactive energy (Class 2 accuracy)
electromagnetic compatibility Electrostatic discharge immunity class III
Electrical fast transient burst immunity class IV
Surge (shock) immunity Class IV
Security Power frequency withstand voltage Between communication and signal input, AC4kV 1min
Insulation resistance Input and output terminals to casing >100MΩ
Communication Interface and communication protocol RS485 interface and Modbus RTU protocol
Communication address range Modbus RTU:1~ 247
Baud rate Support 1200bps-38400bps
Environment Operating temperature 40ºC~+70ºC
Storage temperature 40ºC~+70ºC
Relative humidity ≤95℅ (without condensation)
Altitude 3000m
Supporting transformer specifications
Ordering specifications Current transformer parameters Number of transformers
ADL400N-CT/D10 80A/26.6mA 3
ADL400N-CT/D16 120A/40mA 3
ADL400N-CT/D24 200A/66.6mA 3
ADL400N-CT/D36 300A/100mA 3
 

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

Appearance

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation SystemsAdl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation SystemsAdl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation SystemsAdl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

LCD Display

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

Wiring

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

ADL400N-CT Three-phase Four-wire Connection Through Current Transformer

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

ADL400N-CT Three-phase Three-wire Connection Through Current Transformer (this connection method is limited to three-phase balance) (instrument is set as 3P4L)

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
ADL400N-CT Three-phase Three-wire Connection Through Current Transformer (instrument is set as 3P3L)
Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems
ADL400N-CT Single-phase Three-wire Connection Through Current Transformer
Installation Instructions

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

Networking

Adl400n/CT Programmable DIN Rail Three-Phase Multi-Functional Energy Meter with RS485 LCD Display for New Energy Power Generation Systems

FAQ

Q: What's the difference of current input via direct connect or via CTs?

A: Normally, for 3-phase loads with rated current below 80A AC, we will use model of ADL400 whose current input is via direct connect. Specs of "Rated Current: 10(80)A AC" was aimed for this model of ADL400 (current input via direct connect). 10 means basic current is 10A AC, 80 means rated current input is 80A AC.

And for 3-phase loads with rated current over 80A AC, we will use model of ADL400 whose current input is via CTs (usually paired with -/5A CTs whose secondary current output is with 5A AC rated current output). Specs of "Rated Current: 1(6)A AC" was aimed for this model of ADL400 (current input via CTs). 1 means basic current is 1A AC, 6 means max current input is 6A AC.

 

Q: Do your company also have paired CTs for ADL400?

A: Usually, we will recommend our user to use split-core CTs called AKH-0.66/K K-φ Series or solid-core CTs called AKH-0.66/I Series to the paired with ADL400 (current input via CTs)

 

Q: How can I set the CT or PT ratio of ADL400?

A: Current ratio of ADL400 could be set by using the keypads on ADL400 and following the instruction of ADL400 manual. Also, setting need to be according to the CTs or PTs ratio which were paired with ADL400. For example, if the current input is via 250A/5A CTs, the CT ratio on ADL400 should be set to 250/5=50. And if the voltage input is via direct connect, PT ratio on ADL400 should be set to 1. When the problem hasn't been solved, please contact us for help.

 

Q: Could ADL400 be used in IoT Energy Monitoring System for factory or building?

A: ADL400 has standard RS485 interface and MODBUS-RTU communication protocol which allow it to be integrate with our IoT Energy Monitor Solution that can enable our users to remotely check all the data collect by energy meters like ADL400 on their mobile phone or PC. For more information, please Contact us or check in IoT Energy Monitoring Solution Introduction.

 

Q: What is Multi-rate/tariff function? How does it work?

A: First,multi-rate/tariff function was designed to be used for billing system. Second, the electricity price of different time duration in a day is different in some country.

Energy meter with this function can measure the kwh data and assign them to several time duration in a day and put a label of spike/peak/flat/valley kwh on them respectively. And if such energy meter was connected to the billing system by using a IoT gateway, it can send the kwh data of different time duration which was with the label of spike/peak/flat/valley kwh to the billing system for calculating the electricity bill of different time duration in a day.

For example, the electricity price of spike kwh is 5 USD/1 kwh, and time duration of from 9:00 am to 11:30 am was labeled as spike kwh.
Then, if energy meter record 3 kwh used in total during 9:00 am to 11:30 am, it will send the data of 3 kwh with the label of spike kwh to the billing system, and the system calculate the electricity cost of 3x5=15USD in total from 9:00 am to 11:30 am.