With the rapid growth of data centers, their energy consumption has become increasingly significant. Energy management and the design of power supply and distribution for data centers have become pressing issues. Implementing an efficient and reliable power distribution system in data centers is crucial for improving power consumption efficiency and reducing equipment energy usage. To achieve energy savings, it is essential to monitor each electrical load. However, due to the numerous load circuits in data centers, traditional measuring instruments fall short in terms of cost, size, installation, and construction requirements. Therefore, a multi-circuit monitoring device suitable for centralized monitoring in data centers is necessary.
The AMC16Z series AC precision power distribution monitoring device is specifically designed for data center server power management. This well-designed device can provide A + B dual input and 96 output electrical parameters, and it offers real-time monitoring of the input and output switches as well as the status of lightning protection devices. Each measurement channel's alarm threshold can be set individually. When an over-outgoing condition occurs, the system triggers an immediate audio-visual alarm. This device achieves highly integrated monitoring within the traditional instrument's size constraints.
Function&Parameter
AMC16Z-ZA | Monitor the full power parameters of A+B double-way three-phase AC incoming circuit, 6-way switch state monitoring, 2-way alarm output, 2-way leakage monitoring, 1-way temperature and humidity detection, 1-way RS485 communication, and phase-sequence detection. |
AMC16Z-FAK24 | Monitor the full power parameters and switch state of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment. |
AMC16Z-FAK48 | Monitor the full power parameters and switch state of 48 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment. |
Technical parameters |
AMC16Z-FAK24 |
AMC16Z-FAK48 |
Measurement parameters |
Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power, switching state |
|
Rated Bus Voltage |
220VAC | |
Rated Current |
50mA | |
Input frequency |
45~60Hz | |
Communication |
RS485/Modbus-RTU | |
Installation method |
DIN35mm Guide rail or bottom plate mounting |
Technical parameter |
AMC16Z-ZA |
Measured parameters | Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power |
Zero ground voltage, neutral line current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF),telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity, environmental temperature and humidity. |
|
Rated voltage |
220VAC |
Current incoming circuit |
0~6A |
Input frequency |
45~60Hz |
Switch output |
2-way 3A 250VAC/3A 30VDC |
Switch input |
6-way dry contact |
Communication |
RS485/Modbus-RTU |
Installation method |
DIN35mm Guide rail or bottom plate mounting |
Dimension
Network