Suppliers with verified business licenses
Base station dedicated DC energy meter AMC16(L)-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure 6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software. have the functions of tele-metering,tele-indication,tele-adjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction. This meter can measure DC power consumption of three operators, providing detail datas for base station.
Technical Parameter
|
Value
|
|
Input
|
DC Rated Voltage
|
1 Channel: -48VDC
|
DC Current
|
6 Channels Hall Sensor Output is 5V, Current Ratio Can be Set According to the Actual Ratio
|
|
Commercial Power Monitoring
|
1 Channel: 0-5VDC
|
|
Overload Capacity
|
Voltage: 1.2 Times Continued, 2 Times Continued 1s
|
|
Current: 1.2 Times Continued, 10 Times Continued 1s
|
||
Accuracy (Superposition Hall Sensor)
|
1% In ≤ I ≤ 10% In Error ±2.5%; I>10% In Error ±2%
|
|
Measurement Resolution
|
Voltage Output Accuracy 0.01V; Current Output Accuracy 0.01A;
Power Output Accuracy 0.01kW; Energy Output Accuracy 0.01kWh
|
|
Auxiliary Power Supply
|
Voltage Range
|
-40V~-60VDC
|
Power Consumption
|
Whole Device ≤ 2W (No Hall Power Supply Output)
|
|
Storage
|
It has the storage function of historical power data and historical alarm information, and the memory is 2MB
|
|
Insulation Resistance
|
≥40MΩ
|
|
Environment
|
Temperature
|
Working: -20-60ºC; Storage: -40-70ºC
|
Humidity
|
≤98% No Condensation, No Corrosive Gas Place
|
|
Altitude
|
≤4000m
|
|
Protection Level
|
IP20
|
|
Material Flame Retardent
|
Terminal Glow Wire Temperature 960ºC ±10ºC, Shell Glow Wire Temperature 650ºC ±15ºC
|
|
Installation
|
Standard 35mm Din Rail
|
|
Lighting Protection
|
Voltage Input (Differential Mode)
|
Peak Value 5kA
|
Auxiliary Power Supply (Differential Mode)
|
Peak Value 5kA
|