Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Still deciding? Get samples of US$ 185/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (24)
  • Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
  • Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
  • Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
  • Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
  • Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
  • Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
AIM-D100-T
Model Number
Aim-D100-T
Maximum Power Consumption
Less Than 6W
Operating Temperature
-40~+75 Centigrade
Insulation Resistance Range
1 Kilo-Ohm~10 Megohm
Communication
RS485 Interface, Modbus-RTU Protocol
Warning and Alarm Range
10 Kilo-Ohm~10 Megohm
System Leakage Capacitance
Less Than 5μf
Alarm Method
LCD, LED Indicator, Relay Output
Installation
DIN-Rail Installation
Color
White
Brand
Acrel
Transport Package
Carton
Specification
70*72*108mm
Trademark
Acrel
Origin
China
HS Code
9030849000
Production Capacity
10000pieces/Month

Product Description

Product Description

AIM-D100-T series DC Insulation Monitor

 

Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
With the development of industry, many electrical equipment and plant equipment are powered by DC systems, which have ungrounded positive and negative terminals. For ungrounded (IT) distribution system, insulation resistance should be monitored to ensure the safe operation of the power supply system.AIM-D100-T series DC insulation monitor can be applied in 10~1000V DC system for on-line monitoring of DC ungrounded system positive and negative pole to ground insulation resistance, and send out warning or alarm signal when insulation resistance is lower than the set value.


  The product is based on the principle of unbalanced bridge, which avoids the problem that balanced bridge can not detect the insulation resistance when there are ground faults at both positive and negative poles. The product can be applied to DC systems such as DC panels of power plants and substations, electric vehicle charging devices, UPS power supply systems, photovoltaic DC systems, energy storage systems and other DC power grids

Model Description

Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV ChargerAcrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger
 

Product Parameters

 
Technical Parameter
Technical Specifications
Auxiliary power
DC 9~36V
Maximum power consumption
≤6W
 
 
Voltage
monitor
Voltage range
AIM-D100-TH: DC 100~1000V;
AIM-D100-TL: DC 10~100V
Accuracy
0.5
Overvoltage threshold
≥110% Rated Voltage
Undervoltage threshold
≤90% Rated Voltage
 
 
Insulation
monitoring
Insulation resistance range
1kΩ~10MΩ
Warning and alarm range
10kΩ~10MΩ
Accuracy
1~10kΩ: ±1k; 10k~500k: ≤3%
System leakage capacitance
≤5μF
Monitoring method
Cycle trigger: 5~500s delay can be set;
Communication trigger: read on demand
Insulation monitoring speed
500ms/cycle; 1000ms/cycle
 
Internal DC impedance
<1MΩ
Alarm method
LCD, LED indicator, relay output
Alarm output
3 relay outputs, N/O or N/C can be set
Contact capacity
5A 250V AC;5A 30V DC
Fault Record
20 fault record
Communication
RS485 interface, Modbus-RTU protocol
Installation
DIN-rail installation
Protection level
IP30
 
 
 
Environment
Operating temperature
-40~+75ºC
Storage temperature
-40~+125ºC
Relative humidity
<95%, without condensation
Altitude
<2000m

 

 

Company Profile

Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger

Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV ChargerAcrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger

Packaging & Shipping

Acrel Aim-D100-T Series DC Insulation Monitoring Device for EV Charger

FAQ

Q:Where is your company located?
A:Our headquarter is in Shanghai, our factory locates in Jiangyin,Jiangsu Province,China.
It takes about 1 hour by car from Shanghai Hongqiao International Airport to our factory

Q:What's your lead time?
A:Sample time 1-3days,mass production 10~20days for order more than 500pcs

Q:Payment terms?
A:Usually,TT,credit card,western union,in cash and so on.You can also choose to pay 30% as deposit and the balance before shipment.

Q:What certifications do you have ?
A:We have ISO9001,IEC,CE and so on.


Q:Can other logo be put on your products(OEM)?
A:Yes,but MOQ for OEM will be at least 100pcs.We also need you provide logo Ai Format or EPS.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier