After-sales Service: | 2 Years |
---|---|
Warranty: | 2 Years |
Display: | Digital |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
*Current measurement
*LCD Display
*Single Phase Ammeter
*Input:1A or 5A
1.General
AMC series programmable intelligent meters,adopting AC sampling technology,can directly or indirectly measure electric voltage and current of single phase or three phase grid. It can be used for local display,and connecting industrial control device to form measuring control system.
2.Function
Accuracy : Active energy:Class 0.5
Frequency : 45-65Hz
Auxiliary power supply: AC/DC 85-265V
Rated current : AC 5A or 1A
Consumption:
Current : Power consumption< 0.5VA;
Auxiliary power supply: Power consumption≤10VA
Optional Function:
RS485 communication (Modbus-RTU)
4-20mA analog output
Technical Parameters | Value | |
Input | Connection | Single phase-2 wire,3 phase-3 wire,3 phase 4-wire |
Frequency | 45-65Hz | |
Voltage | Rating: Single-phase:AC 100V,400V Three-phase:AC 3x57.7V/100V(100V),3x220V/380V(400V) 3x380V/660V(660V)(96 size only) Note:72 profile not suitable for high voltage application |
|
Overload:1.2 fold rating(continuous):2 fold rating for 1 second | ||
Power consumption:<0.5VA | ||
Current | Rating:AC 1A,5A | |
Overload:1.2 fold rating(continuous):10 fold rating for 1 second | ||
Power consumption:<0.5VA | ||
Output | Electric energy | Output mode:open-collector photo-coupler pulse |
Pulse constant:10000imp/kWh(settable),see wiring diagram for details | ||
Communication | RS485 port,Modbus-RTU protocol,DLT645 protocol(versions 09 and 97),baud rate 1200-38400 | |
Function | Switching input | Dry contact input,built-in power supply |
Switching output | Output mode:Relay normally open contact output | |
Contact capacity:AC 250V/3A,DC 30V/3A | ||
Analog output | 1-5V,4-20mA | |
Accuracy Class | Frequency:0.05Hz,Current,Voltage;0.2 class,Reactive Power:1.0 class,Reactice Electric energy:1.0 class active Power:0.5 class,active electric energy:0.5 class,2-31th harmonic measurement:±1% |
|
Power Supply | AC/DC 85-265V Power consumption≤10VA | |
Security | Power frequency withstand voltage |
Between Power supply//Switching Output//Current input//voltage input and Transmitting//Communication//Pulse Output//switching input AC 2kV 1min; Between Power supply,switching output,Current input,voltage input AC 2kV 1min; Between Transmitting,Communication,Pulse Output,switching input AC 1kV 1 min; |
Insulation resistance | Input,Output end to machine enclosure>100MΩ | |
Environment | Temperature | work:-25ºC~+65ºC storage:-40ºC~+80ºC |
Humidity | ≤93%RH Non-condensing | |
Altitude | ≤2500m |
Suppliers with verified business licenses