• Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor
  • Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor
  • Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor
  • Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor
  • Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor

Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor

After-sales Service: 2 Years
Warranty: 2 Years
Display: Digital
Samples:
US$ 122.5/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor pictures & photos
Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor
US $122.5 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
  • Overview
  • Product Description
  • Feature
  • Technical Parameters
  • Application
  • Company Profile
  • Packaging & Shipping
  • Exhibition
Overview

Basic Info.

Model NO.
AMC16MA
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter, Data Center
Electric Equipment
Three-phase Three-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, CE
Customized
Non-Customized
Input Incoming Current
0-9999A
Input Outgoing Current
120A
Incoming Line Current Output
5A
Outgoing Line Output
20mA
Voltage
AC220V
Communication
Modbus-RTU/RS485
Transport Package
Paper Carton
Specification
194*124*88mm
Trademark
Acrel
Origin
Jiangsu China
HS Code
9028301400

Packaging & Delivery

Package Size
35.00cm * 32.00cm * 25.00cm
Package Gross Weight
2.000kg

Product Description

Product Description
Acrel AMC16 series multi-circuit monitoring device is specially designed for the power management of center data server in data center. This device is small and exquisite, which can monitor electric parameters and switching state from as many as dozens of circuits besides input circuit and output circuit in a centralized way. It realizes high centralization of monitoring circuits in the dimension of traditional meter.
 
Feature
Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor
Input voltage AC220V, input current AC 5A,self-setting transformer ratio,
outlet current transformer ratio AC100A/20mA,
2 inlet testing and 36 single phase(or 12 3-phase) outlet
testing,
1 switching output.
Communication protocol: RS485 port Modbus/RTU protocol,
Power supply:AC220V

 

 
Technical Parameters
Functions of AMC16MA multi circuit energy meter
Model
Functions
Optional communication
AMC16MA
Measuring incoming main line 3 phase voltage
1.RS485/Modbus 2.DC48V power supply
incoming line: 2 channel 3 phase I,Kw,Kvar,cosφ,Kwh
(current, active power, reactive power, power factor, active energy, reactive energy)
outgoing line: 36 channel single phase (12 channel 3phase)I,Kw,Kvar,cosφ,Kwh,Kvarh(need to allocate AHK-0.66W 100A/20mA CTs
inbuilt communication:1 channel RS485
1 DO, aux. power supply:AC 220V
 
Parameters of AMC16MA acrel
Bus voltage
Rated input voltage
AC220V
Measurement range
AC 40~400V
Overload
instantaneous voltage twice/30 seconds
Current circuits
rated input current
inlet:5A outlet:20mA
measurement range
inlet:5-10000A outlet:0.25-125A
Overload
sustained voltage1.2times,instantaneous current 10times/5 seconds
Frequency
45-60HZ
Auxiliary power
AC80-270V or DC100V-350V/DC48V±20%
accuracy
current,voltage class: 0.5 power,energy: 1
Relay output
5A/250VAC or 5A/30VDC
Communication
RS485-MOBUS-RTU protocol
Installation
Din rail 35mm
 
Application

Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor

 

Company Profile

Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor

Packaging & Shipping

Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor

Exhibition

Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor pictures & photos
Acrel Amc16mA Measure Incoming Line AC Current Multi-Circuit Energy Meter for Data Center Energy Monitor
US $122.5 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
40
Year of Establishment
2017-07-25