AMC series intelligent power collection and monitoring device is a smart meter designed for power monitoring needs of power systems, industrial and mining enterprises, utilities, and intelligent buildings.
Accuracy:Active energy:Class 0.5
Frequency: 45-65Hz
Auxiliary power supply: AC/DC 85-265V
Phase: 3P4W
Consumption:
Voltage: Power consumption <0.5VA;
Current: Power consumption< 0.5VA;
Auxiliary power supply:power consumption≤10VA
Measurement: 3-phase AC kWh, kVarh, I, U, kW, kVar, Hz, cosφ and etc
Analog Output: 4-20mA DC or 1-5V DC
Communication: RS485(Modbus-RTU)
DI/DO:2/4-channel DI & 2-channel DO
SOE Records: Event&Demand&Extremum
Harmonic: 2~31st and total Harmonic
Technical Parameters | Value | |
Input | Connection | Single phase-2 wire,3 phase-3 wire,3 phase 4-wire |
Frequency | 45-65Hz | |
Voltage | Rating: Single-phase:AC 100V,400V Three-phase:AC 3x57.7V/100V(100V),3x220V/380V(400V) 3x380V/660V(660V)(96 size only) Note:72 profile not suitable for high voltage application |
|
Overload:1.2 fold rating(continuous):2 fold rating for 1 second | ||
Power consumption:<0.5VA | ||
Current | Rating:AC 1A,5A | |
Overload:1.2 fold rating(continuous):10 fold rating for 1 second | ||
Power consumption:<0.5VA | ||
Output | Electric energy | Output mode:open-collector photo-coupler pulse |
Pulse constant:10000imp/kWh(settable),see wiring diagram for details | ||
Communication | RS485 port,Modbus-RTU protocol,DLT645 protocol(versions 09 and 97),baud rate 1200-38400 | |
Function | Switching input | Dry contact input,built-in power supply |
Switching output | Output mode:Relay normally open contact output | |
Contact capacity:AC 250V/3A,DC 30V/3A | ||
Analog output | 1-5V,4-20mA | |
Accuracy Class | Frequency:0.05Hz,Current,Voltage;0.2 class,Reactive Power:1.0 class,Reactice Electric energy:1.0 class active Power:0.5 class,active electric energy:0.5 class,2-31th harmonic measurement:±1% |
|
Power Supply | AC/DC 85-265V Power consumption≤10VA | |
Security | Power frequency withstand voltage |
Between Power supply//Switching Output//Current input//voltage input and Transmitting//Communication//Pulse Output//switching input AC 2kV 1min; Between Power supply,switching output,Current input,voltage input AC 2kV 1min; Between Transmitting,Communication,Pulse Output,switching input AC 1kV 1 min; |
Insulation resistance | Input,Output end to machine enclosure>100MΩ | |
Environment | Temperature | work:-25ºC~+65ºC storage:-40ºC~+80ºC |
Humidity | ≤93%RH Non-condensing | |
Altitude | ≤2500m |
1)Opening in fixed distribution cabinet