DTSD1352-4S series DIN-rail type multi-circuit power meter is mainly used for the full electric parameter measurement of multiple circuits, and can be connected to the current input of 4 three-phase circuits or 12 single-phase circuits at the same time. It can measure parameters such as voltage and current, power, power factor, phase angle, unbalance, and harmonics.
Auxiliary Power | AC/DC 85~265V or DC 40-60V; power consumption≤10VA; | ||
Input Signal | Frequency | 45~65Hz; | |
Voltage | Rated value: AC 3×220V/380V; | ||
Overload: 1.2 times rated value (continuous); 2 times rated value/1 second; | |||
power consumption: ≤ 0.5VA(each channel); | |||
Current | Rated value: Secondary input rated current:50mA | ||
Overload: 1.2 times rated value (continuous); 10 times rated value/1 second; | |||
power consumption: ≤ 0.5VA(each channel); | |||
Measurement Accuracy | Frequency: 0.05Hz, voltage and current: 0.5 class, active energy: 1 class, reactive energy: 2 class; 2nd to 31st harmonic accuracy: ±1%; | ||
Function | Pulse output | Output method: optocoupler pulse with open collector,the pulse constant defaults to 400imp/kWh (and active open input can only be either-or.); | |
communication | RS485 interface, Modbus-RTU protocol; baud rate 1200~38400; | ||
Switch | Input | 2-way or 4-way passive dry contact input, built-in power supply; 2-way active wet node input (AC220V), identify the oil generator and mains access (and pulse output can only be either-or.); |
|
Output | Output method: relay normally open contact output; Contact rating: AC 250V/3A DC 30V/3A; |
Safety | Power frequency withstand voltage | >AC 2kV/1min; |
Insulation resistance | Input and output terminals to the chassis >100MΩ; | |
Environment | Operating temperature:-20ºC~+60ºC; Storage temperature:-40ºC~+70ºC; Relative humidity:≤95% no condensation; Altitude:≤2500m; |
|
Electromagnetic Compatibility | better than 3 class; |
The current transformer is a crystal head interface, the primary side current is 50A-600A . If the current transformer is different, the customer can modify the current transformation ratio through the instrument interface or communication according to the actual use. The transformer is shown in Figure 1 and Figure 2.
DTSD1352-4S Matching current transformers
Note: For special transformers, please contact for specific consultation.
Shape Dimension(mm) | Rail Dimension(mm) | Tolerance(mm) | ||||
Length | Width | Heigth | with terminal length | |||
Single Module | 87.8 | 72 | 71.5 | 97.7 | 35 | ±1 |
Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.