Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Still deciding? Get samples of US$ 122.5/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (24)
  • Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line
  • Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line
  • Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line
  • Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line
  • Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line
Find Similar Products
  • Overview
  • Product Description
  • Feature
  • Technical Parameters
  • Application
  • Company Profile
  • Packaging & Shipping
  • Exhibition
Overview

Basic Info.

Model NO.
AMC16MA
Display
Digital
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter, Data Center
Electric Equipment
Three-phase Three-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, CE
Customized
Non-Customized
Input Incoming Current
0-9999A
Input Outgoing Current
120A
Incoming Line Current Output
5A
Outgoing Line Output
20mA
Voltage
AC220V
Communication
Modbus-RTU/RS485
Transport Package
Paper Carton
Specification
194*124*88mm
Trademark
Acrel
Origin
Jiangsu China
HS Code
9028301400

Packaging & Delivery

Package Size
35.00cm * 32.00cm * 20.00cm
Package Gross Weight
2.000kg

Product Description

Product Description
Acrel AMC16 series multi-circuit monitoring device is specially designed for the power management of center data server in data center. This device is small and exquisite, which can monitor electric parameters and switching state from as many as dozens of circuits besides input circuit and output circuit in a centralized way. It realizes high centralization of monitoring circuits in the dimension of traditional meter.
 
Feature
Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line
Input voltage AC220V, input current AC 5A,self-setting transformer ratio,
outlet current transformer ratio AC100A/20mA,
2 inlet testing and 36 single phase(or 12 3-phase) outlet
testing,
1 switching output.
Communication protocol: RS485 port Modbus/RTU protocol,
Power supply:AC220V
Technical Parameters
Functions of AMC16MA multi circuit energy meter
Model
Functions
Optional communication
AMC16MA
Measuring incoming main line 3 phase voltage
1.RS485/Modbus 2.DC48V power supply
incoming line: 2 channel 3 phase I,Kw,Kvar,cosφ,Kwh
(current, active power, reactive power, power factor, active energy, reactive energy)
outgoing line: 36 channel single phase (12 channel 3phase)I,Kw,Kvar,cosφ,Kwh,Kvarh(need to allocate AHK-0.66W 100A/20mA CTs
inbuilt communication:1 channel RS485
1 DO, aux. power supply:AC 220V
 
Parameters of AMC16MA acrel
Bus voltage
Rated input voltage
AC220V
Measurement range
AC 40~400V
Overload
instantaneous voltage twice/30 seconds
Current circuits
rated input current
inlet:5A outlet:20mA
measurement range
inlet:5-10000A outlet:0.25-125A
Overload
sustained voltage1.2times,instantaneous current 10times/5 seconds
Frequency
45-60HZ
Auxiliary power
AC80-270V or DC100V-350V/DC48V±20%
accuracy
current,voltage class: 0.5 power,energy: 1
Relay output
5A/250VAC or 5A/30VDC
Communication
RS485-MOBUS-RTU protocol
Installation
Din rail 35mm
 
Application

Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line

 

Company Profile

Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line

Packaging & Shipping

Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line

Exhibition

Acrel Data Center Electricity Consumption Monitoring Multi-Circuit Energy Meter Measure Incoming and Outgoing Line

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier