• Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
  • Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
  • Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
  • Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
  • Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery

Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery

Type: Lead-Acid Batteries
Usage: Car, Bus, UPS, Electric Power, Lighting, Electric Bicycle, Boat
Nominal Voltage: 2V
Samples:
US$ 16/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery pictures & photos
Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
US $16 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
ABAT100-S-02
Discharge Rate
Low Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Open Frame
Rechargeable
Non-Rechargeable
Display
Real-Time Data Display, Graphs, Histogram Display
Historical Data
Query and Export of Equipment Operation History, C
Parameter Configuration
Provide Basic Information Management Functions
Communication Protocol
Modbus-RTU
Alarm Mode
Local Audible and Visual Alarm, Indicator Alarm, S
Capacity Estimation
Group Batteries Soc, Soh Estimation; Single Batter
Transport Package
Carton
Trademark
Acrel
Origin
China

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
0.500kg
Lead Time
1 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

1 Overview
Acrel ABAT100 series battery online monitoring system can provide battery operation information such as voltage, internal resistance and internal temperature, including SOC and SOH, and can provide early warning and battery equalization for failed batteries to guarantee battery pack backup time and extend battery pack life. The system has monitoring functions, and is easy to install, maintain and access. The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.

2 Product Module
Model                        Function Description
ABAT100-HS DC24V input, one to manage a group of batteries, up to 120 batteries in a group.
ABAT100-S-02 Monitor one 2V battery, monitor battery voltage, internal resistance and negative terminal temperature.
ABAT100-S-06 Monitor one 6V battery, monitor battery voltage, internal resistance and negative terminal temperature.
ABAT100-S-12 Monitor one 12V battery, monitoring battery voltage, internal resistance and negative terminal temperature.
ABAT100-C Monitor one charge/discharge current with an ambient temperature with a maximum current range of 1000A.

Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery3 Product Description
3.1 ABAT100-HS Collector Module 
Introduction
The ABAT100-HS collector module is used as a management module for a group of battery packs to read the battery monitoring data from the front-end single battery monitoring sub-module and analyze and process the data, which can estimate the remaining capacity of each battery and the whole group of batteries. The operation parameters can be set directly by matching with the touch screen, and the collected data can be viewed directly. The collector module will automatically save the key battery data periodically and can be sent to the third party monitoring system through RS485 port, supporting MODBUS protocol. One collector module manages one group of batteries, and the maximum number of manageable modules is 120.

Abat100-S-02 Monitor One 2V Battery for Lead-Acid BatteryAbat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
Function Description
Display Real-time data display, graphs, histogram display
Historical Data Query and export of equipment operation history, charging and discharging records and monitoring events
Parameter Configuration Provide basic information management functions
Communication protocol MODBUS-RTU
Alarm mode Local audible and visual alarm, indicator alarm, SMS alarm, etc.
Capacity estimation Group batteries SOC, SOH estimation; single battery SOC, SOH estimation
Regular inspection Intelligent judgment of the current state and automatic issuance of test commands
Indicator light Red and green LED lights, green light as the power light, red light as the indicator light
Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
Technical parameters Description
Working Environment Operating temperature: -10ºC~50ºC
Relative humidity: 5%~95%
Atmospheric pressure intensity: 80~110kPa
Management Capability One collector can monitor a maximum of total 120 batteries
Alarm Type Group voltage overcharge/discharge, single voltage overcharge/discharge, current overcharge/discharge, high internal resistance of single unit, abnormal communication, etc.
Power Supply DC24V
Protection With overvoltage and short circuit protection
Communication Interface With RS485 communication port, support MODBUS/RTU
Insulation withstand voltage 2000VAC
Installation method Tie-down mounting or adhesive mounting
Weight 90g
3.2 ABAT100-S Single Battery Monitoring Module
Introduction
ABAT100-S single battery monitoring module (S module) can be embedded into existing monitoring system to achieve online monitoring of each backup battery voltage, internal resistance and negative battery temperature, in accordance with ANSI/TIA-942 standard requirements. The monitoring system controls and reads data by sending MODBUS commands to the S-module, and performs internal resistance testing, each S-module has a settable address. S-modules are extremely simple and easy to install and wire, and can be directly attached to the battery with detachable connecting wires, which does not affect the battery operation during construction.

 
Function Description
Online monitoring Online monitoring 24 hours a day, one battery per module, monitoring voltage, internal resistance and negative terminal temperature
High accuracy measurement Internal resistance measurement error as low as 1%
Battery internal resistance test Automatic periodic measurement of the internal resistance of each battery controlled by the collector
Low power design Manual entry into low power mode, S-module draws current from the battery down to 0.5mA
Anti-jamming design High anti-interference design, can block the ripple interference of high power high frequency UPS
Communication protocol MODBUS-RTU protocol
Installation method Tie-down mounting or adhesive mounting
Indicator light Red and green LED lights, green light as the power light, red light as the indicator light
Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
Technical parameters Description
Working Environment Operating temperature: -10ºC~50ºC
Relative humidity: 5%~95%
Atmospheric pressure intensity: 80~110kPa
Monitoring Capability One S-module monitors one battery
Monitoring Scope 2V, 6V, 12V battery with capacity less than 3000AH
Measurement range and accuracy Measurement content Scope Accuracy
Single Voltage 2V, 6V, 12V ±0.1%
Single internal resistance 50~65535uΩ (Resolution) 1uΩ
Negative temperature -5ºC~+105ºC ±1°C
Power requirements
 
Directly from the monitored battery, 2V module normal operation of the absorption current of 10mA, the maximum is not more than 13mA, 6V, 12V module normal operation of the absorption current of 5mA, the maximum is not more than 7mA, different modules absorption current consistency is very high
Protection Measuring circuit and power circuit with two levels of protection, with reverse connection protection and opto-isolation
Communication Interface UART port, support MODBUS protocol
Insulation withstand voltage 2000VAC
Weight 90g
3.3 ABAT100-C Module 
Introduction
The ABAT100-C battery monitoring module (C module) can be embedded into existing monitoring systems for online monitoring of battery charge and discharge current and ambient temperature. The monitoring system controls and reads data by sending MODBUS commands to the C-module, and each C-module has a settable address. the C-module is extremely simple and easy to install and wire, and can be directly attached to the battery with removable connection cable, which does not affect the battery operation during construction.

 
Function Description
High stability Reliable and stable long-term operation
Anti-jamming design High anti-interference design, can block the ripple interference of high power high frequency UPS
Communication protocol MODBUS-RTU Protocol
Installation method Tie-down mounting or adhesive mounting
Indicator light Red and green LED lights, green light as the power light, red light as the indicator light.
Technical parameters Description
Working Environment Operating temperature: -10ºC~50ºC
Relative humidity: 5%~95%
Atmospheric pressure intensity: 80~110kPa
Monitoring Capability One C-module monitors the charge and discharge current of a group of batteries against the ambient temperature
Monitoring Scope 2V, 6V, 12V battery pack
Measurement range and accuracy Measurement content Scope Accuracy
Charging and discharging current 0~1000A ±1%
Ambient temperature -5ºC~+105ºC ±1°C
Power requirements DC24V, 1W
Protection Measurement circuit and power circuit with two levels of protection
Communication Interface UART port, support MODBUS protocol
Insulation withstand voltage 2000VAC
Weight 90g

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery pictures & photos
Abat100-S-02 Monitor One 2V Battery for Lead-Acid Battery
US $16 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
40
Year of Establishment
2017-07-25