• Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V
  • Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V
  • Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V
  • Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V

Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V

After-sales Service: 24h Online
Warranty: 2 Years
Display: Digital
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V pictures & photos
Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V
US $50 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
AMC96L-E4/KC
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, CE
Customized
Customized
Connection
Single Phase-2-Wire, 3-Phase-3-Wire, 3-Phase-4-Wir
Frequency
45-65Hz
Power Consumption
< 0.5va
Communication
RS485port, Modbus -RTU Protocol,Dlt645 Protocol
Transport Package
Carton
Trademark
Acrel
Origin
China
HS Code
9028301400

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
1.000kg
Lead Time
1 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

1.General

 AMC series intelligent power collection and monitoring device is a smart meter designed for power moni toring needs of power systems, industrial and mining enterprises, utilities, and intelligent buildings. It integrates measurement of power parameters (such as single-phase or three-phase current, voltage, and active power). Power, reactive power, apparent power, frequency, power factor) and power monitoring and assessment management. At the same time, it has a variety of peripheral interface functions for users to choose: with RS485 communication interface, MODBUS-RTU protocol can meet the needs of communication network management; 4-20mA analog output can correspond to measured electrical parameters, meet DCS Such interface requirements; with switch input and relay output can realize the function of "remote signal" and "remote control" of circuit breaker switch. High-brightness LED/LCD display interface, parameter setting and control through buttons, ideal for real-time power monitoring systems. Can directly replace conventional power transmitters and measuring instruments. As an intelligent, digital front-end acquisition component, the instrument has been widely used in various control systems, SCADA systems and energy management systems.

2.Type and specification of products
Meter type Basic function Optional function  
AMC72L-E4/KC Three phase voltage, Zero sequence voltage
Three phase current, Zero sequence current
Three phase active power, Total active power
Three phase reactive power, Total reactive power
Three phase apparent power, Total apparent power
Three phase Power factor, Total power factor
Frequency, Voltage phase angle, Voltage and current imbalance,Forward and reverse power
Four quadrant energy metering,System time display
1 channel RS485 interface / Modbus-RTU protocol and the statute DLT645.
2DI+2DO+1Ep(K)
4DI+2DO(K)
Compound rate(F)
T2-31 th and total harmonics measurement (H)
2DI+2DO+1M(KM)
 
AMC72-E4/KC 2DI+2DO+1Ep(K)
4DI+2DO(K)
Event record (SOE)
T2-31 th and total harmonics measurement (H)
2DI+2DO+1M(KM)
 
AMC96L-E3/KC
AMC96L-E4/KC
Three phase voltage, Zero sequence voltage
Three phase current, Zero sequence current
Three phase active power, Total active power
Three phase reactive power, Total reactive power
Three phase apparent power, Total apparent power
Three phase Power factor, Total power factor
Frequency, Voltage phase angle, Voltage and current imbalance,Forward and reverse power
Four quadrant energy metering,System time display
1 channel RS485 interface / Modbus-RTU protocol and the statute DLT645.
4DI+2DO+1Ep(K)
2DI+2DO+1Ep(K)
Compound rate(F)
2-31th harmonic
measurement (H)
2-channel analog output (2M)
1-channel analog output (M)
2DI(220V)+2DO+1EP(KA)
 
AMC96-E3/KC
AMC96-E4/KC
4DI+2DO+1Ep(K)
2DI+2DO+1Ep(K)
Event record (SOE)
2-31th harmonic
measurement (H)
2-channel analog output (2M)
1-channel analog output (M)
2DI(220V)+2DO+1EP(KA)
 
AMC72-E/KC
AMC72L-E/KC
single-phase voltage,single-phase current
active power, reactive power, apparent power
Power factor
Frequency
Four quadrant energy metering,System time display
1 channel RS485 interface / Modbus-RTU protocol and the statute DLT645.
2DI+2DO+1Ep(K)
4DI+2DO(K)
Event record (SOE)
Total harmonic
measurement (H)
2DI+2DO+1M(KM)
 
3.Technical parameters
 Technical parameters Value
Input Connection Single phase-2-wire, 3-phase-3-wire, 3-phase-4-wire
Frequency 45-65Hz
Voltage Rating:
single-phase :AC 100V,400V
Three-phase: AC 3×57.7V/100V(100V),3×220V/380V(400V),3×380V/660V(660V)(96 size only)
Overload:1.2 fold rating {continuous) : 2 fold rating for 1 second
Power consumption:< 0.5VA
Current Rating: AC IA,5A
Overload:1.2 fold rating(continuous);10fold rating for 1 second
Power consumption:< 0.5VA
Output Electric energy Output mode:open-collector photo-coupler pulse
Pulse constant: 10000imp/kWh(settable),see wiring diagram for details;
Communication RS485port, Modbus -RTU protocol,DLT645 protocol(versions 07 and 97),
baud rate 1200 ~ 38400
Function Switching input Dry contact input, built-in power supply;if the model is KA,it is AC 220V active.
Switching output Output mode: Relay normally open contact output
Contact capacity: AC 250V/3A, DC 30V/3A
Analog output 4 - 20mA
 Accuracy class Frequency:0.05Hz,Current,Voltage:0.2 class,Reactive power:l .0class,Reactive Electric energy:l .0class, active power:0.5class,active electric energy: 0.5class,2-31th harmonic measurement:±1%
 Power supply AC/DC 85-265V or DC24V(±20%)or DC48V(±20%)
power consumption≤10VA
Security Power frequency withstand voltage Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min;
Between Power supply,switching output,Current Input,voltage Input AC 2 kV 1min;
Between Transmitting,Communication,Pulse Output,switching input AC 1kV 1 min;
Insulation resistance Input,Output end to machine enclosure >100MΩ
Environment Temperature work: -25°C~+65°C  storage: -40°C ~+80°C
Humidity ≤93%RH Non-condensing
Altitude ≤2500m

Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V
Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690VAmc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V pictures & photos
Amc96L-E4/Kc Panel Type 3p4w Enregy Meter for 690V
US $50 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
40
Year of Establishment