• Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
  • Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
  • Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
  • Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
  • Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
  • Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU

Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU

After-sales Service: 2 Years
Warranty: 2 Years
Display: Digital
Installation: Indirect Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment: Three-phase Three-wire
Samples:
US$ 35/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
AMC96-AI3
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, CE
Customized
Non-Customized
Frequency
45-65Hz
Input Current
AC 1A 5A
Power Supply
AC/DC85-265V
Display Type
LED
Phase
Three Phase
Transport Package
Paper Carton
Specification
96x96mm
Trademark
Acrel
Origin
Jiangsu China
HS Code
9028301400
Production Capacity
99999pieces/Year

Product Description

Three phase 5A input amp panel meter led display ammeter digital with Modbus-rtu
AMC96-AI3 adopting AC sampling technology, can directly or indirectly measure electric voltage and current of single phase or three phase grid. It can be used for local display, and connecting industrial control device to form measuring control system.
The have RS-485 port,adopt Modbus-RTU protocol. Analog output, alarm output, switching input/output can be selected. Based on different request, by pressing the keys,parameters of ratio,alarm,communication etc.can be modified.
 
Products Size
Shape
Panel
Housing
Cutout
Unit:mm
Width
Height
Width
Height
Depth
Width
Height
96 Square
96
96
90
90
77.8
92
92
Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
Products Installing
1)Make holes on distribution cabinets;
2)Take out the meter and the buckle;
3)The meter is loaded into the mounting hole from the front ;
4)Insert the buckle and fix the meter.
Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
Technical parameter
Value
Input
Rated value
AC voltage: Single phase AC100V,400V 
Three phase AC100V,400V,660V(UL-L,Only72/96)
AC current:AC1A,5A;
DC voltage:1000V,300V,75mV,10V;
DC current:0-20mA,4-20mA,5A;
Overload
Voltage:1.2 times rated value(continuous); 2 times rated value/ 1 second; 
Current:1.2 times rated value (continuous); 10 times
rated value/1 second.
Frequency
45Hz~65Hz
Power consumption
Power consumption of each voltage, current input circuit is less than 0.5VA
Accuracy
0.5
Function
Display
LED or LCD
Communication
RS485,Modbus-RTU protocol;(1 start bit, 8 data bit, 1 stop bit, no parity) Baud Rate 2400/4800/9600/19200 bps etc.
Alarm
1 channel passive relay, contact capacity 3A/30VDC, 3A/250VAC, Used for high,low,unbalance alarmetc.
Analog
DC4~20mA,(load<500Ω)(note:Shielded wire is specially selected for the above signal input and output)
switching
Input
4 channel or 2 channel dry contact Input, built in power supply
Output
2 channel switching output,NO relay contact, capacity:3A/30VDC,3A/250VAC
Auxiliary supply
Voltage range
AC/DC85-265V
Power consumption
<5VA
Insulation resistance
>100MΩ
Power frequency with stand voltage
Between power supply set of terminals and signal input, output set of terminals 2kV/1min (RMS) 
Between the shell and all set of terminals (except the set of terminals reference voltage less than40V) AC4kV
Environment
Temperature
Operation:-10ºC~+55ºCStorage:-25°C~+70°C
 
Humidity
≤95%RH,no condensation,without corrosive gas
 
Altitude
≤2500m
Packing & Delivery                                                                                   
1. Payment:100% TT in advance,credit card and western union. For large amount, we can accept terms T/T 30% in advance as deposit and balance 70% before delivery.

2. Delivery:in 3-10 working days after payment received.

3. Delivery ways:By sea,air,train or international courier like Fedex,TNT,DHL and so on.


Our Company                                                                                            
Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
Company Exhibition                                                                                 Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
Product Certifications                                                                              
Three Phase 5A Input AMP Panel Meter LED Display Ammeter Digital with Modbus-RTU
 
Contact                                                                                                       


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now