Technical parameters | AMB100/AMB110 | |
Measured parameters | Voltage, current, power, electric energy, on/off status | |
Voltage | Rated value | 48VDC,240VDC,336VDC |
Range | ±20% | |
Overloading | 1.2 times than the rated voltage value continuously or 2times than the rated voltage value instantaneously persecond | |
Current | CT | 5V(Hall transducer) |
Range | ||
Overloading | 1.2 times than the rated current value continuously or 10times than the rated current value instantaneously persecond | |
Measurement accuracy | Voltage/current: grade 0.5;power/energy: grade 1.0 | |
Auxiliary power supply | AMB100/110-D(/W): trigered upon receipt of requestsignal AMB100/110-D(/W)-P1:follow the bus bar voltage |
|
Functions | Temperaturedetection | -20~150ºC |
Leakage | 5VDC, 3 leakage inputs | |
Digital input | 4 dry-contact inputs | |
Digital output | 2relayoutputs;contactcapacity:3A/30VDC,3A/250VDC | |
Communication | Via RS485/Modbus-RTU or LORA antenna | |
Installation | Use Din35mm rail | |
Protection | IP20 | |
Pollution level | 2 | |
Environment | Temperature/humidity/altitude | Working temperature:-20-+60ºCStorage temperature:-25-+70ºCRelative humidity:<93%Altitude:≤2500m |
Safety | Insulation | The minimum insulation resistance between all terminalsand conductive components of the shell is 100MO. |
Withstanding voltage | When a voltage of 2kV AC is applied between thevoltage/ current input, relay output,RS485 port,auxiliarypower supply and digital inputs,the leakage shall be lessthan 2mA and no breakdown or flashover shall occur in1min. |
Acrel Data Center Busway Monitoring system is a common name for the power supply and distribution system at the end of the data center. This system is mainly used for power distribution at the end of the cabinet in the data center room. It has the characteristics of simplicity, multi-function, speed and economy. There are many advantages. AMB intelligent small busbar management system is a solution for the monitoring requirements of data center intelligent small busbars. It can monitor various parameters during the operation of the busbar, and give an alarm when a fault occurs, so as to ensure the stable operation of the system.