Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv

Phase: 3
Electricity Type: Ac
Number of Pole: 8
Samples:
US$ 777/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv pictures & photos
Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv
US $777 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
AM5SE
Load
Medium Power Relay
Protective Characteristics
Sealed Relay
Action Principle
Electronic Type
Size
Subminiature
Type
Electric Parameter Relay
Input Current
1A/5A
Input Voltage
AC 100V
Functions
8 Current Input, 4 Voltage Input, 16 Di, 10 Do
Communications
2RS485
Display
LCD
GPS Timing
1 GPS
Power Supply
AC/DC110V 220V,DC48V
Warranty
2 Years
Transport Package
Paper Carton
Specification
267*164mm
Trademark
ACREL
Origin
Jiangsu, China
HS Code
9028301400
Production Capacity
1000PCS/Week

Packaging & Delivery

Package Size
20.00cm * 30.00cm * 26.00cm
Package Gross Weight
5.000kg

Product Description

Product Description

Acrel AM5SE Feeder Differential Protection Relays for substations under 35KV

AM5SE Feeder Differential Protection Relays for substations under 35KV

AM5 series microcomputer protection devices are applicable to the user substation in which the input voltage is 35kv or above. AM5 can be used to protect and control the user substation and is being widely used in Power Industry, Water conservancy industry, Traffic Industry, Oil industry, Chemical industry, Coal Industry, Metallurgical Industry, and so on.
Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv

 

 

Functions and parameters

Main functions of AM5 Protection Relay for medium voltage under 35KV

AM5 Series Protection Relay

A complete set of protection, related to the application;
8 current input, 4 voltage input, 16 DI, 10 DO;
Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V;
2 RS485 serial communication, IEC 60870-5-101, IEC60870-5-103 and Modbus-RTU;
1 RS232 for user update;
1 GPS for GPS timing;
More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
Powerful graphic programmable Logic.

 
Rich protection functions

Feeder protection; Transformer protection; Motor protection; Capacitor protection; Voltage protection; Bus tie protection.

 
Measurement
RMS current values; RMS voltage values; frequency; Power factor; RMS active power.

 
Control functions

Remote control; Local control; Programmable switchgear interlocking
Data sheet
Function Specification
-F -C -M -T -B 0 -DB
Hardware Current acquisition 8 8 8 8 6 0 6
Resource Voltage acquisition 4 4 4 4 6 4 6
  Switch Collection 16 16 16 16 16 16 16
  Relay Output 10 10 10 10 10 10 10
Protection Three-stage overcurrent protection          
Three-stage overcurrent with direction blocking            
Two-stage overcurrent protection      
Zero-sequence overcurrent protection      
Inverse time overcurrent protection    
Overload protection        
Control circuit disconnection alarm  
Under-voltage protection         √alarm  
Lack of voltage protection            
PT disconnection alarm
Three-phase one-time reclosing            
Low-frequency load shedding            
High-frequency protection            
After accelerating overcurrent        
Overvoltage protection     √alarm √alarm
Locked-rotor protection              
Undervoltage protection            
Unbalanced voltage protection          
Unbalanced current protection          
Phase error protection            
Zero sequence overvoltage protection     √alarm  
Non-electric protection      
Starting over time            
Reverse power protection            
Thermal overload protection            
Negative sequence overcurrent            
(two stages / inverse time limit)
Incoming line / busbar          
Busbar charging protection            
FC blocking      
Second harmonic blocking      
Intermittent ground protection          
Overhaul status lockout
Communication protocol ModBus-RTU
IEC60870-5-103
Accessibility Fault recorder  
IRIG-B time synchronization
Dimensions and Wirings
 Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv

Dimensions
Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv
Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv
FAQ


Q: How to set the CT and PT ratio of the protection device?

A: The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.


Q: For AM5, if you want to place single circuit protection and transformer protection, how to distinguish the model?

A: AM5-F is suitable for line protection and transformer protection.No need to distinguish between models when placing orders


Q: When the voltage is a three-phase three-wire system, does the current have to be connected with 2CT?

A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.


Q: How to confirm whether the anti-trip function is configured?

A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)


Q: How to purchase suitable protection devices?

A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv pictures & photos
Acrel Am5se Feeder Differential Protection Relays for Substations Under 35kv
US $777 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
40
Year of Establishment
2017-07-25