• Apm800 Full Electricity Energy Power Meter with 0.5s Class
  • Apm800 Full Electricity Energy Power Meter with 0.5s Class
  • Apm800 Full Electricity Energy Power Meter with 0.5s Class
  • Apm800 Full Electricity Energy Power Meter with 0.5s Class
  • Apm800 Full Electricity Energy Power Meter with 0.5s Class
  • Apm800 Full Electricity Energy Power Meter with 0.5s Class

Apm800 Full Electricity Energy Power Meter with 0.5s Class

After-sales Service: 24h Online
Warranty: 2 Years
Display: Digital
Samples:
US$ 240/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Apm800 Full Electricity Energy Power Meter with 0.5s Class pictures & photos
Apm800 Full Electricity Energy Power Meter with 0.5s Class
US $240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
APM800
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, CE
Customized
Customized
Electrical Network
Three-Phase Three-Wire, Three-Phase Four-Wire, See
Frequency
45-65Hz
Protection Level
Display Panel IP52
Transport Package
Carton
Trademark
Acrel
Origin
China
HS Code
9028301400

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 12.00cm
Package Gross Weight
1.000kg
Lead Time
2 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

5.1.Overview
APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology.
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module, event recording (SOE) module with T-Flash (TF) card, network communication module, Temperature and humidity measurement module, can achieve full power measurement of electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize high-speed data transmission and networking function.

2.Type and specification

 
Function APM800
(class 0.5s)
APM801
(class 0.2s)
APM810
(class 0.5s)
Measured parameters Total electrical measurement
Four-quadrant energy
Pulse output of energy Pulse output of active/reactive energy
Demand Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)
Extreme value statistics Extremum of current, line voltage, phase voltage, active power, reactive power, apparent power, power factor, frequency, total harmonic of current, total harmonic of voltage in this month and last month (including time stamp)
Power quality Unbalance of current, line voltage, phase voltage
Voltage phase angle, current phase angle
Voltage current phase Angle
Total (odd, even) harmonic content of voltage and current × ×
Harmonic content of voltage and current (2-63 times) × ×
Voltage crest factor × ×
Telephone waveform factor × ×
Current K-factor × ×
Alarm records A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card
Event log Record the most recent 128 event records, support extended records by TF card
Communication Modbus protocol
I/O 2 digital inputs + 2 digital outputs (2DI+2DO)
Extensions MD82 8 digital inputs + 2 digital outputs with changeover contacts (8DI+2DO)
  MLOG TF card storage (alarm records, event records, electrical parameters and energy timing records, etc.)
MA84 8 analog inputs (class 0.5) + 4 analog outputs (class 0.5) (8AI+4AO)
MCM 1 RS485/Modbus-RTU, support master mode or slave mode
MCP 1 Profibus-DP
MCE 1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol
MTH 4 ways 2m of temperature measurement, 1 way of temperature and humidity control
4 ways 4m of temperature measurement,1 way of temperature and humidity control
MTP 2 ways of  PT100 temperature measurement
MTH 1 way of temperature and humidity control
3.Technical Parameters
Technical Parameters Index
Signal Electrical network Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency 45~65Hz;
Voltage Rated value:AC 100V,110V,400V,690V;
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption: < 0.5VA (per channel);
Current Rated value: AC 1A, 5A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption: < 0.5VA (per channel);
Measurement accuracy Voltage,current and power class 0.5s/class 0.2s (APM800,APM810/APM801)
Active power class 0.5s/class 0.2s (APM800,APM810/APM801)
Reactive power class 2
Harmonic 1%(2rd~42nd),2%(43rd~63rd)
Switch inputs Dry contact inputs, built-in power supply;
Relay outputs Contact type: open contact in main part, changeover contact in module;
Contact capacity:AC 250V/3A  DC 30V/3A;
Pulse output of energy Output mode: Optocoupler pulse with open collector;
Pulse constant:4000(5A),8000(1A) imp/kWh;
Analog outputs DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω;
Analog inputs DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V iutput, accuracy class 0.5%
Storage card Standard Capacity:4G,TF Card Up to 32G Capacity;
Communication RS485 interface/Modbus-RTU protocol and DLT645 protocol
Profibus-DP interface/Profibus-DP protocol;
RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;
Power supply Working range: AC/DC 85V~265V or AC/DC 115~415V(P2);
Power consumption: Power consumption of the main part ≤ 15VA;
Safety Power frequency withstand voltage The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min;
Insulation resistance Inputs,outputs to the shell>100MΩ;
Electromagnetic compatibility Meet IEC 61000 standard (Level 4);
Protection level Display panel IP52
Environment Operating temperature: -20 °C ~ +65 °C;
Storage temperature: -20°C~+70°C;
Relative humidity: ≤95% without condensation;
Altitude: ≤2500m;
Standards IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Part 2-1:Tests Test B:Dry heat
Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h)
IEC 61000-4 Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12 Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c -Equipment for testing,measuring or monitoring of protective measures- Part12:
Performances measuring and monitoring devices(PMD)
IEC 62053-22 Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s)
4.Installation and wiring instructions
Apm800 Full Electricity Energy Power Meter with 0.5s Class5.Wiring

Apm800 Full Electricity Energy Power Meter with 0.5s Class

6.Networking

Apm800 Full Electricity Energy Power Meter with 0.5s Class
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Apm800 Full Electricity Energy Power Meter with 0.5s Class pictures & photos
Apm800 Full Electricity Energy Power Meter with 0.5s Class
US $240 / Piece
Min. Order: 1 Piece
Diamond Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
40
Year of Establishment